Research Article |
Corresponding author: Elena V. Devkina ( edevkina@yandex.ru ) Academic editor: Yury Korovin
© 2022 Elena V. Devkina, Igor R. Suslov, Vladimir A. Chernov.
This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Citation:
Devkina EV, Suslov IR, Chernov VA (2022) Carrying out calculations of radiation safety during unloading and disassembly of cores of spent removable parts of reactors with liquid metal coolant of submarines. Nuclear Energy and Technology 8(4): 247-251. https://doi.org/10.3897/nucet.8.96563
|
The results of calculations conducted to substantiate radiation safety while handling spent removable sections (SRS) of reactors with a liquid metal coolant (LMC) for nuclear submarines (NS) are presented in the article. The spent removable sections of reactors with liquid metal coolant for nuclear submarines are the sources of intense neutron and gamma radiation. Shielding should ensure the dose rate level for neutrons and gamma radiation which is not exceeding the values allowed for transportation of nuclear materials established by the NP-053-04 therefore it will attenuate emission of neutrons and gamma quanta by several orders of magnitude.
A homogeneous model of the reactor core was used for calculations. Sources of neutrons and photons in the spent nuclear fuel (SNF) of the SRS, sources of photons in the reactor control devices and in construction materials (the reactor vessel and grids of fuel rods) have been taken into consideration while conducting the calculations. The computer code MCNP-4B was employed to calculate dose rates for neutrons and photons.
In most cases direct calculations of dose rates for neutrons and secondary gamma-quanta using the MCNP-4B code provided acceptable results with admissible methodical errors. For the tasks with sources of gamma quanta direct calculation using the MCNP-4B brought unsatisfactory results due to strong attenuation.
Various methods were applied to reduce dispersion: the first one is to assign importance to the cells and the second one is the method of weight windows iteration.
Values of dose rates were obtained with acceptable errors. The results of the calculations provided necessary information to conduct operations to unload spent nuclear fuel from the SRS. The results of performed calculations were also used in the design and manufacturing of the shielding.
Spent removable section of reactor (SRS), equivalent dose rate (EDR), method to assign various importance in the cells, method of weight windows
In 1962–1990 several nuclear submarines (NS) with liquid metal (lead-bismuth) coolant (LMC) in the primary coolant circuit were registered in the Russian naval forces (
Operation of NS reactor installation at power levels is accompanied with generation and accumulation of long-lived radioactivity in the reactor core, control and protection rods, in adjoining structures and in the coolant. Its amount in each NS depends on the overall power generation of reactors (
The SRS of the reactors with LMC are the sources of intensive neutron and gamma radiation (
Handling of the SRS includes a series of technological operations when dismantling, reloading and transportation of the SRS and assemblies with spent fuel are carried out. One needs to ensure nuclear and radiation safety while performing these operations.
Calculations assuming individual approach to each SRS are necessary for:
The program code MCNP-4B was used to calculate dose rates for neutron and photon radiation. The Program MCNP-4B is attested for simulation of neutron and photon transportation while conducting calculations of radiation shielding and substantiation of radiation safety of facilities employing nuclear energy including calculations of neutron flux density and absorbed dose of photons for containers with spent nuclear fuel (The Program Complex MCNP4B 2007).
Neutron sources in fuel were taken into account while conducting the calculations. Sources of photon radiation from fission products in the fuel, from europium in the control system, from construction materials (reactor vessels and grids of fuel rods) were considered.
A homogeneous model of the reactor core was employed for calculations of radiation safety. The reactor core was substituted with a cylinder which volume is equal to that of the reactor core. In total 27 control elements were inserted into the cylinder. Five homogeneous zones were identified along the height: bottom grid of fuel rods, reflector, homogeneous fuel, compensation volume and top grid of fuel rods. The following sources were taken into consideration in the performed calculations: sources of neutrons and gamma-quanta from the spent fuel, sources of gamma-quanta from elements of the control system, sources of gamma-quanta from grids of fuel rods and the reactor vessel.
Homogenous source of neutrons and gamma-quanta from spent fuel was set in the fuel zone without profiling along its height and radius. The source from the control system was represented by 27 cylinders coinciding in size and location with the real control elements. It was assumed that each of the 27 sources of radiation contributes equally to the formation of EDR. The homogeneous volume source from fuel rod grids was assigned for the top and bottom grids. The source for the reactor vessel was defined in form of a cylindrical ring without height profiling. Separate calculation was performed for each type of the source (neutron radiation, residual radioactivity etc.). Calculation model of the SRS is presented in Fig.
Dose rates were calculated in reference points. Precalculated reference points were chosen for assemblies in containers in order to estimate the maximum dose rate. For the SRS dose rates were calculated in places where the personnel are present. Location of reference points is shown in Figs
Local estimate we used to calculate the dose rate. The results with errors below 5% are considered to be reliable, results with errors from 5 to 10% are estimated as doubtful and results with errors in excess of 10% are not taken into consideration (The Program Complex MCNP4B 2007). These are the values of errors of the Monte-Carlo method provided by the program. Errors related to the transfer from the real physical to the calculation model (geometry, sources, material composition, constants etc.) are not taken into consideration.
In most cases calculations of dose rates performed for neutrons and secondary gamma-quanta, direct calculation using the MCNP-4B code provided acceptable results with admissible methodical errors below 5%. For the tasks with sources of gamma quanta direct calculation using the MCNP-4B brought unsatisfactory results due to strong attenuation of radiation.
Various methods were applied to reduce dispersion: the first one is to assign importance to the cells and the second one is the method of weight windows iteration.
The method to assign various importance values consists in the approach when different importance values are assigned to the cells. In case of direct calculations using the MCNP-4B each geometrical zone (cell) is assigned with the value of importance which is equal to 1. Values of importance are increasing in the direction of particle motion (in the given case it is from the center to the periphery). The values of importance must differ between neighbouring cells by a factor of two to three (
The method of weight windows iteration is the automated method of weight windows generation where in difference to hybrid methods only the results of Monte-Carlo (MCNP-4B) calculations are used to obtain the weight windows.
In practice it is easier to use the iteration method than the hybrid one because it is not necessary to create the calculation model for the grid code and to intercorrelate the calculation models for MCNP-4B and the grid code. With the help of the iteration method we succeeded to obtain the EDR values with acceptable accuracy for all phases of SRS dismantling and SNF handling.
The method of weight window iteration consists of several steps. At first the calculation is carried out using the MCNP-4B code where distribution of particle fluxes is determined within the whole phase space with the help of the fmesh estimation. The calculated results are used subsequently in the program MESHMOD, which generates the weight windows. The simplest procedure of data reconstruction is employed in the program MESHMOD. Zero values in the grid cells are substituted with arithmetical mean value (ΣΦi)/n) or with geometrical mean values (ΠΦi)1/π over the neighbouring cells. As a result one obtains sufficiently smooth distribution which however is wide from the real one. This distribution is suitable for subsequent calculations. Calculation with weight windows obtained at the first step is conducted at the second step and the results of these calculations are then used by the MESHMOD program to generate weight windows which are used at the following step. The cycle is continued till necessary accuracy is achieved. Dose estimates for the points are assigned during the last iteration. Most of the tasks are converging after the third iteration (
Maximum total calculated dose rates (from gamma-quanta and neutrons) (in µSv/h) on the surface and at a distance of 2 meters for containers 1 and 2 as well as for the SRS at a distance of 50 cm from the surface are presented in Table
Tk-6 | TUK 108/1 | SRS in the holding frame | |
---|---|---|---|
On the surface | 1171.80 | 1368.46 | 8.52 |
At a distance of 2 meters for containers, 50 cm for SRS | 36.21 | 158.22 | 15.70 |
The obtained calculated dose rates for different types of radiation satisfy the requirements of the NP-053-04 (
Results of calculations for gamma-quanta mostly demonstrate good agreement with the readings of dose-meters. The results of neutron dose rate calculations show decrease in comparison with the readings of dose meters. As a whole results of calculations provided information to carry out unloading of spent nuclear fuel from the SRS. The calculated results were also used in design and manufacturing of the shielding.
Calculation for the benchmark experiment used in verification of computer programs was conducted to explain the discrepancy between the experimental and calculated data for neutron dose rates. This benchmark (
Comparison of experimental and calculated data is presented in Fig.
Difference between the experimental and calculated data on the integral fluence is within the error limits of the spectrometer (10%).
The chosen calculation model describes real construction of containers and radiation shielding quite well. The simulated sources take main types of radiation into consideration.
Sources which are used in the calculation model consider all types of radiation.
Direct calculation using the MCNP-4B code is not always providing the results with admissible methodical accuracy. For simple geometry it is better to use the method where different values of importance are assigned to cells, for more complex geometry it is better to use the method of weight windows iteration.
As a whole the calculated results provided necessary information to carry out operations on the unloading of spent nuclear fuel from the SRS.