Corresponding author: Victor I. Slobodchuk ( slobovic@mail.ru ) Academic editor: Yury Korovin
© 2021 David A. Hakobyan, Victor I. Slobodchuk.
This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Citation:
Hakobyan DA, Slobodchuk VI (2021) Temperature conditions in the RBMK spent fuel pool in the event of disturbances in its cooling mode. Nuclear Energy and Technology 7(1): 9-13. https://doi.org/10.3897/nucet.7.64363
|
The problems of reprocessing and long-term storage of spent nuclear fuel (SNF) at nuclear power plants with RBMK reactors have not been fully resolved so far. For this reason, nuclear power plants are forced to search for new options for the disposal of spent fuel, which can provide at least temporary SNF storage. One of the possible solutions to this problem is to switch to compacted SNF storage in reactor spent fuel pools (SFPs). As the number of spent fuel assemblies (SFAs) in SFPs increases, a greater amount of heat is released. In addition, no less important is the fact that a place for emergency FA discharging should be provided in SFPs. The paper presents the results of a numerical simulation of the temperature conditions in SFPs both for compacted SNF storage and for emergency FA discharging. Several types of disturbances in normal SFP cooling mode are considered, including partial loss of cooling water and exposure of SFAs. The simulation was performed using the ANSYS CFX software tool. Estimates were made of the time for heating water to the boiling point, as well as the time for heating the cladding of the fuel elements to a temperature of 650 °С. The most critical conditions are observed in the emergency FA discharging compartment. The results obtained make it possible to estimate the time that the personnel have to restore normal cooling mode of the spent fuel pool until the maximum temperature for water and spent fuel assemblies is reached.
Nuclear power plant, reactor, spent fuel pool, spent nuclear fuel, temperature conditions
The life of the operating RBMK-1000 units and the existing storage conditions for spent nuclear fuel (SNF) at NPP sites require that the number of SNF storage sites should be increased. One of the possible temporary solutions to this problem is to switch to compacted SNF storage in reactor spent fuel pools (SFPs). The amounts of fuel stored in the SFP are increased by transferring SFAs to non-canister compacted storage. Owing to this, between the beams of the SFP slotted overlap, it is possible to place 2.4 times more SFAs than in standard (canister) fuel storage. However, as the number of SFAs in the SFP increases, so does the amount of heat released by them. In this regard, it becomes necessary to carry out thermohydraulic calculations of the SFPs in order to substantiate the safety of compacted SNF storage. In addition, it is required that a place for emergency FA unloading should be provided in the SFP.
The SFPs are resistant to emergency situations: because of their stable structure severe accidents in them have long been considered as unlikely events in which the operators will have enough time to take adequate corrective actions. The Fukushima Daiichi nuclear disaster, which followed the earthquake in Japan on March 11, 2011, renewed interest in the safety of SNF stored in SFPs during loss-of-coolant accidents (LOCAs) (
In general, there are four different thermohydraulic scenarios that can arise during LOCAs in SFPs:
- fuel assemblies are completely covered with water;
- partially exposed but undamaged SFAs;
- partially exposed but damaged SFAs; and
- completely exposed SFAs (
When the SFP normal cooling system is inoperative, heat is removed from the SFAs due to natural convection of water and air and is dissipated into the environment. Evaporation can also play a significant role as the water temperature rises (
If the water level in the pool is lower than the upper part of a spent fuel assembly, this does not necessarily lead to immediate heating of its exposed part. As long as the water level is not much lower than the upper part of the SFA, the exposed part can be cooled by the steam flow and the rise in the water level due to its boiling in the lower part. The calculations carried out in (
This paper considers the following scenarios:
- computational analysis of the thermal hydraulics of the SFP model during the compacted SNF storage in the event of disturbances in the SFP normal cooling conditions; and
- computational analysis of the temperature conditions in the SFP compartment, into which emergency SFA discharging is provided, in the event of disturbances in the SFP normal cooling conditions.
A study was carried out concerning modes with the termination of the SFP cooling and with partial loss of cooling water in the SFP with the exposure of SFAs by 20, 25 and 50%.
Figures
For the computational model, the SFA was represented by a solid cylinder 78 mm in diameter and 7 m in height. The sling model consists of two cylindrical parts: one part with a diameter of 78 mm and a height of 4.93 m and the other one with a diameter of 36 mm and a height of 3.57 m. The space between the SFAs in the SFP was filled with water (or water and air when the assembly was partially exposed). For the calculation, the equivalent properties of the SFAs were used. The equivalent properties of the assembly model were set from the condition of equality of the maximum temperature of the SFA model and the fuel element of a real assembly at the same temperature of the outer surface Tout and at the same thermal power of the SFA model and all the fuel elements of a real fuel assembly. In the model with compacted FA storage in the SFP, the heat release corresponded to a maximum power of 1.951 MW (
Numerical simulation of the temperature conditions in the SFP emergency discharging compartment is the most acceptable analytical tool, since the experimental study of such situations is problematic. The calculation was carried out using the ANSYS CFX software (
The properties of the materials used for constructing the computational model (fuel, fuel element cladding, stainless steel, water, air) were taken from (
The obtained model was used to calculate the temperature conditions in the SFP during compacted SFA storage for a stationary state when forced circulation was stopped. The calculation results showed that even if the SFP was fully filled with water, the water was heated to the boiling point. Natural circulation was hindered due to the rather close arrangement of the SFAs; a significant portion of the heat was transferred by thermal conductivity.
In order to determine the time of water heating to the boiling point, calculations for transient conditions were carried out. It was shown that, when the forced circulation was stopped, the water in the SFP was heated to 90 °C in 90,700 s (25.19 hours), and it heated up to the boiling point in 126,500 s, or approximately 35.1 hours (Fig.
For the SFP model, the following options were considered: exposure of the SFAs in the SFP by 20, 25 and 50%, i.e., some of the SFAs are in the water and some are in the air. First, calculations were carried out for stationary conditions in order to determine the onset of the “limit” state, i.e., heating the water to the boiling point or heating the fuel assemblies to 650 °C. The results obtained showed that only when no more than 20% is exposed, the SFA temperature does not reach the limit value of 650 °C. With greater exposure of the assemblies, the SFA temperature noticeably exceeds the limit values. In all the considered cases, the water temperature reached the boiling point (Tboil = 100 °C). The next step was the calculation of transient conditions in order to estimate the time for heating the water in the SFP to the boiling point and heating the SFAS to the temperature of 650 °C.
As expected, the exposed part of the assemblies in the air was heated to a higher temperature as compared to the part in the water. This led to the fact that the upper water layer was heated rather quickly to the boiling point, while the lower layers were at temperatures lower than the saturation temperature. The maximum water temperature in time with partial exposure of the SFAs changed practically according to a linear law, which was a consequence of the accepted assumption of a uniform SFA axial power distribution. This time was approximately 7.5 hours (Fig.
As for the emergency SFA unloading compartment, the time for heating the water to the boiling point and heating the SFAs to 650 °C was significantly less as compared to the compacted SFA storage compartment. The calculation results showed as follows: with a decrease in the volume of water in the SFP to the level of the SFA heads, the boiling temperature was reached in 2.5 hours; when the SFAs were exposed by 25%, it would take 1.84 hours; and when the SFAs were exposed by 50%, the water would boil in 1.56 hours (Fig.
Figure
The paper considers the temperature conditions in the spent fuel pool of a power unit with the RBMK-1000 reactor during compacted SFA storage and during emergency SFA unloading. The authors considered options with disturbances in the SFP cooling conditions, including partial loss of water and exposure of SFAs.
The calculations showed that, in the case of compacted SFA storage, when they were exposed no more than by 20%, their temperature did not exceed 650 °C, and the water in the pool was heated to the boiling point in approximately 7.5 hours. With greater exposure of the SFAs, the spent assembly itself could be heated to a temperature noticeably higher than 650 °C.
The assessment showed that the time of water heating in the emergency FA unloading compartment decreased from 2.5 hours (with a decrease in the water volume in the SFP to the level of the SFA heads) to 1.56 hours when the fuel assemblies were exposed by 50%. When the SFAs were exposed to 50%, their claddings were heated to 650 °C in 1.12 hours, i.e., faster than the water was heated to the boiling point.
The results obtained can be considered as an estimate of the time that personnel have to restore the SFP cooling conditions.