Research Article |
Corresponding author: Anatoly A. Kazantsev ( akazancev@ippe.ru ) Academic editor: Yury Kazansky
© 2023 Anatoly A. Kazantsev, Ol’ga V. Supotnitskaya, Evgeniya A. Ivanova, Irina V. Moskovchenko, Ruben I. Mukhamadeev, Vladimir F. Timofeev, Nataliya E. Astakhova.
This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Citation:
Kazantsev AA, Supotnitskaya OV, Ivanova EA, Moskovchenko IV, Mukhamadeev RI, Timofeev VF, Astakhova NE (2023) Hydrogen explosion safety for the Bilibino NPP EGP-6 reactor in conditions of a beyond design basis accident. Nuclear Energy and Technology 9(2): 121-125. https://doi.org/10.3897/nucet.9.107760
|
The paper presents the results of simulating a beyond design basis accident with regard to radiolytic hydrogen transport and analysis of hydrogen explosion safety in the reactor cavity and in the central reactor hall of the Bilibino NPP. The KUPOL-M code, version 1.10a, is used as the calculation tool for justifying hydrogen explosion safety. The accident under investigation is a beyond design basis accident, the initial event for which is spontaneous travel of two pairs of automatic control rods and a failure of the reactor scram system. The accident leads to the maximum possible release of positive reactivity, mass destruction of fuel elements, and escape of radiolytic hydrogen, as part of the gas mixture, into the reactor cavity and the central hall and further, through the broken windows, into the atmosphere. The calculation results show that no explosive concentrations of hydrogen are formed in the reactor cavity and in the central hall. Therefore, hydrogen explosion safety is ensured throughout the duration of the design basis accident for the Bilibino NPP unit with the EGP-6 reactor.
boiling water reactor, radiolysis products, radiolytic hydrogen, Bilibino NPP, EGP-6, hydrogen explosion safety, beyond design basis accident, KUPOL-M code
The formation of an explosive mixture and its explosion may lead to the wall and equipment breakdown and, further, to the release of radioactive fission products (RFP) into the environment, so hydrogen explosion safety justification issues are indispensable in the NPP design and safe operation justification (
Explosive safety of hydrogen-containing mixtures is characterized by the following criteria:
The state of the art in ensuring hydrogen explosion safety at NPPs and an overview of respective regulatory documents are provided in
The paper considers a beyond design basis accident (BDBA) at a reactor facility with the EGP-6 reactor leading to the maximum release of positive reactivity due to the spontaneous travel of the automatic control rods in response to the scram failure. The BDBA scenario was described earlier in
In reactor conditions, hydrogen is produced as follows in the process of water radiolysis:
2H2O → 2H2 + O2.
After the heat sinks is lost and the FA cladding fails at 800 to 1100 °C, hydrogen is produced as the result of the steam interaction with the magnesium the fuel composition contains according to the following reaction:
Mg + H2O = MgO + H2.
The scenario for the beyond design basis accident (BDBA) under consideration is presented in
An accident involving the insertion of the maximum possible positive reactivity and the scram system failure leads to a neutron power growth to 419% of the rated power and the gradual cladding failure in up to 126 FAs. The cladding heat removal is lost within 30 seconds after the CRs start to move upwards in a spontaneous manner, which leads to a departure from nucleate boiling (DNB) and a surge of coolant boiling. This, in turn, leads to a rapid pressure growth (to 10 MPa), and the reactor circulation circuit rupture and voiding. The DNB leads to the FA cladding overheating and a failure of about a half of all FAs. Hydrogen is produced as the result of the evaporating coolant interaction with the fuel’s magnesium matrix.
The duration of the BDBA under consideration is 1000 s.
Fig.
Bilibino NPP’s central hall with four EGP-6 reactors [www.fotoalbom.su].
Fig.
Sectional view of the EGP-6 reactor: 1 – upper side plate; 2 – larger rotary plate drive; 3 – central frame with supports; 4 – central rotary plate; 5 – risers; 6 – smaller rotary plate drive; 7 – roller bearing; 8 – inserts; 9 – support assemblies; 10 – lower plate; 11 – graphite stack; 12 – CPS channel; 13 – FA; 14 – biological shielding tank; 15 – shroud; 16 – reactor vessel compensator; 17 – upper plate; 18 – group headers with working pipelines;19 – stop valves; 20 – lower layer of safety plate; 21 – central hall (CH).
Conditionally, the development of a beyond design basis accident can be divided into three stages.
Stage I. This stage involves massive fuel cladding failure in 16 maximum-power FAs, this leading to a steam-gas-water mixture (that containing radiolytic hydrogen) formed in the reactor. An abrupt reactor pressure growth of 0.24 MPa causes the welded joint between the reactor’s top plate and the reactor vessel thermal expansion compensator to break down and the plate to lift. The steam-gas-water pressure growth in the space between the reactor head and the upper safety plate leads to the steam-gas-water mixture entering the central hall.
At this stage, hydrogen is produced as the result of the water boiling and the release of the radiolytic hydrogen dissolved in water. Hydrogen is produced additionally as the result of the fuel magnesium matrix reaction with the coolant in 16 FAs whose cladding has failed.
Stage II. An abrupt pressure increase in the CH leads to the central hall windows broken and a steam-gas-water mixture released into the atmosphere. As more primary coolant is lost, the FA cladding temperature grows to 900 °C, which leads to some 100 average-power FAs failing further by the 100th s. The process involves the steam-gas-water mixture escaping additionally, through the graphite stack, into the reactor cavity, the assembly space, the space between the reactor head and the upper safety plate and, further, into central hall and, through the CH windows, into the atmosphere.
Stage III. After the primary coolant is lost in full by the 100th second, 126 FAs fail additionally due to the FA heating to 1100 °C.
Fuel cladding failure was investigated experimentally at IPPE to analyze the consequences of a beyond design basis accident (
Paper
The estimate provided in
The flow rate of the steam-water mixture entering the central hall is shown in Fig.
The release of hydrogen from the reactor cavity into the central hall is defined by two processes: the release of dissolved radiolytic hydrogen in the process of water boiling and the release of hydrogen due to the fuel’s magnesium matrix reaction with steam after some of the FA claddings fail. And the amount of hydrogen resulting from the fuel matrix interaction will be several times as large as the amount of radiolytic hydrogen.
The nodalization model used for the KUPOL-M calculations is shown in Fig.
Figs
Fig.
Fig.
An analysis of the calculation results obtained using the KUPOL-M code has shown that the concentration of steam in the reactor cavity during the accident exceeds 55 vol.%, which ensures hydrogen explosion safety at the BDBA stage discussed.
The volume concentration of hydrogen in the central hall is an order of magnitude as small as the threshold concentration of 4 vol.%, so, accordingly, hydrogen explosion safety is ensured across the simulation range of a beyond design basis accident.