<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//TaxonX//DTD Taxonomic Treatment Publishing DTD v0 20100105//EN" "../../nlm/tax-treatment-NS0.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:tp="http://www.plazi.org/taxpub" article-type="research-article" dtd-version="3.0" xml:lang="en">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">79</journal-id>
      <journal-id journal-id-type="index">urn:lsid:arphahub.com:pub:D015427E-53F6-553C-9279-2E51CD684756</journal-id>
      <journal-title-group>
        <journal-title xml:lang="en">Nuclear Energy and Technology</journal-title>
        <abbrev-journal-title xml:lang="en">NUCET</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="epub">2452-3038</issn>
      <publisher>
        <publisher-name>National Research Nuclear University MEPhI (Moscow Engineering Physics Institute)</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.3897/nucet.7.78339</article-id>
      <article-id pub-id-type="publisher-id">78339</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Research Article</subject>
        </subj-group>
        <subj-group subj-group-type="scientific_subject">
          <subject>Nuclear safety and Radiation protection</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>An expert neural system for diagnostics of motor-driven valves</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author" xlink:type="simple" corresp="no">
          <name name-style="western">
            <surname>Trykov</surname>
            <given-names>Evgeny L.</given-names>
          </name>
          <xref ref-type="aff" rid="A1">1</xref>
        </contrib>
        <contrib contrib-type="author" xlink:type="simple" corresp="yes">
          <name name-style="western">
            <surname>Trykova</surname>
            <given-names>Irina V.</given-names>
          </name>
          <xref ref-type="aff" rid="A2">2</xref>
          <email xlink:type="simple">trykova@kvantprogramm.ru</email>
        </contrib>
        <contrib contrib-type="author" xlink:type="simple" corresp="no">
          <name name-style="western">
            <surname>Kotsoyev</surname>
            <given-names>Konstantin I.</given-names>
          </name>
          <xref ref-type="aff" rid="A2">2</xref>
          <xref ref-type="aff" rid="A3">3</xref>
        </contrib>
      </contrib-group>
      <aff id="A1">
        <label>1</label>
        <addr-line content-type="verbatim">JSC “STC Diaprom”, 6 Koroleva St., rooms 22-23., Obninsk, Kaluga Reg., 249031 Russia</addr-line>
        <institution>JSC “STC Diaprom”</institution>
        <addr-line content-type="city">Obninsk</addr-line>
        <country>Russia</country>
      </aff>
      <aff id="A2">
        <label>2</label>
        <addr-line content-type="verbatim">KVANT PROGRAMM LTD, 5/12 Zeleny Ave., bld. 3, room B1, Moscow, 111558 Russia</addr-line>
        <institution>KVANT PROGRAMM LTD</institution>
        <addr-line content-type="city">Moscow</addr-line>
        <country>Russia</country>
      </aff>
      <aff id="A3">
        <label>3</label>
        <addr-line content-type="verbatim">Bauman Moscow State Technical University, 5 Vtoraya Baumanskaya St., Moscow, 105005 Russia</addr-line>
        <institution>Bauman Moscow State Technical University</institution>
        <addr-line content-type="city">Moscow</addr-line>
        <country>Russia</country>
      </aff>
      <author-notes>
        <fn fn-type="corresp">
          <p>Corresponding author: Irina V. Trykova (trykova@kvantprogramm.ru)</p>
        </fn>
        <fn fn-type="edited-by">
          <p>Academic editor: Georgy Tikhomirov</p>
        </fn>
      </author-notes>
      <pub-date pub-type="collection">
        <year>2021</year>
      </pub-date>
      <pub-date pub-type="epub">
        <day>17</day>
        <month>12</month>
        <year>2021</year>
      </pub-date>
      <volume>7</volume>
      <issue>4</issue>
      <fpage>297</fpage>
      <lpage>302</lpage>
      <uri content-type="arpha" xlink:href="http://openbiodiv.net/90F64B2E-B7E6-5F52-8186-F4D2F0949D0E">90F64B2E-B7E6-5F52-8186-F4D2F0949D0E</uri>
      <history>
        <date date-type="received">
          <day>25</day>
          <month>02</month>
          <year>2021</year>
        </date>
        <date date-type="accepted">
          <day>12</day>
          <month>08</month>
          <year>2021</year>
        </date>
      </history>
      <permissions>
        <copyright-statement>Evgeny L. Trykov, Irina V. Trykova, Konstantin I. Kotsoyev</copyright-statement>
        <license license-type="creative-commons-attribution" xlink:href="http://creativecommons.org/licenses/by/4.0/" xlink:type="simple">
          <license-p>This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.</license-p>
        </license>
      </permissions>
      <abstract>
        <label>Abstract</label>
        <p>Trouble-free operation of motor-driven valves (MDV) is one of the key factors behind the operating safety of NPPs. As critical components, MDVs are a part of a safety system and a safety-related system. This imposes the highest possible requirements on the MDV reliability.</p>
        <p>MDVs are the most numerous category of the NPP components. Depending on design, one power unit contains 1500 to 3000 motor-driven valves alone. It follows from an analysis of the NPP failures that many of these are caused by failed motor-driven valves of safety and safety-related systems.</p>
        <p>The paper presents a description of an automated system for diagnostics of shutoff and control MDVs used in the NPP pipelines. The developed diagnostic algorithms make it possible to take into account the variability of the MDV technical parameters, while taking into account, at the same time, rated restrictions on diagnostic parameters, if any.</p>
      </abstract>
      <kwd-group>
        <label>Keywords</label>
        <kwd>NPP safety</kwd>
        <kwd>motor-driven valves, pipelines</kwd>
        <kwd>diagnostics</kwd>
        <kwd>neural networks</kwd>
        <kwd>segmentation</kwd>
        <kwd>automated system</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <body>
    <sec sec-type="Introduction" id="SECID0E6D">
      <title>Introduction</title>
      <p>In the process of operation, MDVs are exposed to impacts from a large number of factors, infrequently of a random nature, e.g. variation of the fluid and environment parameters. The higher is the variation of the technical condition parameters, the less efficient are the maintenance and repair routine charts, since, in this case, there is always a factor of uncertainty regarding the technical condition of the respective item. Therefore, despite regular preventive maintenance activities, not all MDV defects can be detected on a timely basis.</p>
      <p>The paper presents a diagnostic system which allows fully automated online diagnostics of MDVs at early stages of the failure development. The developed diagnostic algorithms make it possible to take into account the variability of the MDV technical parameters and rated limits for diagnostic parameters if any. An overview of the typical MDV failures is provided in (<xref ref-type="bibr" rid="B4">Adamenkov 2009</xref>, <xref ref-type="bibr" rid="B13">Slepov and Sysoyev 2014</xref>).</p>
    </sec>
    <sec sec-type="Terms and definitions" id="SECID0EOE">
      <title>Terms and definitions</title>
      <p>The paper uses the terms as specified in methodology (<xref ref-type="bibr" rid="B11">MT 1.2.3.02.999.0085-2010</xref>) “Diagnostics of Motor-driven Pipeline Valves.” approved and put into effect by JSC Concern Rosenergoatom’s Order No. 9/270-17, dated 27.03.2012.</p>
      <p>Methodology (<xref ref-type="bibr" rid="B11">MT 1.2.3.02.999.0085-2010</xref>) defines the requirements to the content and organization of activities to evaluate the technical condition of motor-driven shutoff, shutoff and control, and control valves installed in the process systems of NPP units using diagnostic tools and methods.</p>
      <p>The methodology’s requirements apply to valves of safety class 2, 3 and 4, as qualified in NP-001-97 (PNAE G-01-011-97), and of groups B and C under PNAE G-7-008-89 developed as required in NP-068-05, OTT-87, as well as developed prior to OTT-87 was put into effect.</p>
      <p>According to (<xref ref-type="bibr" rid="B11">MT 1.2.3.02.999.0085-2010</xref>), the paper uses the following terms with respective definitions:</p>
      <list list-type="bullet">
        <list-item>
          <p>active power – a quantity equal to the root-mean-square value of the dipole instantaneous power for a particular period (GOST R 52003);</p>
        </list-item>
        <list-item>
          <p>diagnostic (monitored) parameter – a parameter of the item used for its diagnostics (GOST 20911);</p>
        </list-item>
        <list-item>
          <p>cyclogram – a time series (current, voltage, active power, etc.) which describes one MDV opening or closing cycle.</p>
        </list-item>
      </list>
    </sec>
    <sec sec-type="Description of the diagnostic algorithm" id="SECID0E2E">
      <title>Description of the diagnostic algorithm</title>
      <sec sec-type="Initial data" id="SECID0E6E">
        <title>Initial data</title>
        <p>The experience of the MDV operation and an analysis of the electrical machine failures show that the motor current and/or active power signal measured for one or three phases is informative enough for identifying the technical condition type (serviceability evaluation) for the CHP plant or NPP unit process system valves (MT 1.2.3.02.999.0085-20103). The recorded information for the calculation of diagnostic parameters is electrical parameters of the motor stator winding current and voltage.</p>
        <p>The motor (three-phase) stator winding and limit switch current and voltage signals are recorded in real time by measuring modules in the cabinets of the unilateral-maintenance three-phase distribution assembly for gate valves (RTZO) to the database of the data acquisition system. The architecture of the data acquisition system is described in (<xref ref-type="bibr" rid="B10">Matveyev et al. 2009</xref>).</p>
        <p>The MDV diagnostics based on signals of the motor current consumed in the process of the opening and closing operations is considered (<xref ref-type="bibr" rid="B8">Matveyev and Skladnikov 2009a</xref>, <xref ref-type="bibr" rid="B9">2009b</xref>, <xref ref-type="bibr" rid="B3">Abidova et al. 2015</xref>).</p>
      </sec>
      <sec sec-type="Active power cyclogram" id="SECID0EYF">
        <title>Active power cyclogram</title>
        <p>The active power cyclogram calculated based on the current and voltage signals using the formula below plays the key role in diagnostics of failures</p>
        <p><mml:math id="M1"><mml:mi>P</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mfrac><mml:mn>1</mml:mn><mml:mi>T</mml:mi></mml:mfrac><mml:msubsup><mml:mo>∫</mml:mo><mml:mi>t</mml:mi><mml:mrow><mml:mi>t</mml:mi><mml:mo>+</mml:mo><mml:mi>T</mml:mi></mml:mrow></mml:msubsup><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi>τ</mml:mi><mml:mo>)</mml:mo><mml:mo>·</mml:mo><mml:mi>i</mml:mi><mml:mo>(</mml:mo><mml:mi>τ</mml:mi><mml:mo>)</mml:mo><mml:mi>d</mml:mi><mml:mi>τ</mml:mi></mml:math>, (1)</p>
        <p>where <italic>Т</italic> is the carrier frequency period (50 Hz); and <italic>u</italic> (<italic>τ</italic>), <italic>i</italic> (<italic>τ</italic>) are the instantaneous voltage and current values at time <italic>τ</italic> respectively. An example of the active power cyclogram is provided in Fig. <xref ref-type="fig" rid="F1">1</xref>.</p>
        <fig id="F1" position="float" orientation="portrait">
          <object-id content-type="doi">10.3897/nucet.7.78339.figure1</object-id>
          <object-id content-type="arpha">BE5268D2-0ECE-5D8C-A033-9A470A4B4E95</object-id>
          <label>Figure 1.</label>
          <caption>
            <p>Active power cyclogram.</p>
          </caption>
          <graphic xlink:href="nucet-07-e78339-g001.jpg" position="float" orientation="portrait" xlink:type="simple" id="oo_624486.jpg">
            <uri content-type="original_file">https://binary.pensoft.net/fig/624486</uri>
          </graphic>
        </fig>
        <p>Further, diagnostic signs are identified in the active power cyclograms based on which a conclusion is made as to if there is a defect.</p>
      </sec>
      <sec sec-type="Diagnostic system operation algorithm" id="SECID0EPH">
        <title>Diagnostic system operation algorithm</title>
        <p>The diagnostic system operation algorithm is presented in Fig. <xref ref-type="fig" rid="F2">2</xref>.</p>
        <fig id="F2" position="float" orientation="portrait">
          <object-id content-type="doi">10.3897/nucet.7.78339.figure2</object-id>
          <object-id content-type="arpha">8F3E2EB0-F27F-5C69-A7D4-930172709A03</object-id>
          <label>Figure 2.</label>
          <caption>
            <p>Diagnostic system operation algorithm.</p>
          </caption>
          <graphic xlink:href="nucet-07-e78339-g002.jpg" position="float" orientation="portrait" xlink:type="simple" id="oo_624487.jpg">
            <uri content-type="original_file">https://binary.pensoft.net/fig/624487</uri>
          </graphic>
        </fig>
      </sec>
    </sec>
    <sec sec-type="Procedures to obtain diagnostic signs" id="SECID0EZH">
      <title>Procedures to obtain diagnostic signs</title>
      <sec sec-type="Segmentation of the active power signal" id="SECID0E4H">
        <title>Segmentation of the active power signal</title>
        <p>The key idea behind the proposed approach is segmentation of the active power cyclogram with the diagnostic signs identified further by segments (Fig. <xref ref-type="fig" rid="F3">3</xref>).</p>
        <fig id="F3" position="float" orientation="portrait">
          <object-id content-type="doi">10.3897/nucet.7.78339.figure3</object-id>
          <object-id content-type="arpha">567E1A86-2FA5-58FF-9F87-9395C334F44C</object-id>
          <label>Figure 3.</label>
          <caption>
            <p>Segmentation of an active power cyclogram: 1 – motor start (roll); 2 – gate shift (for opening); 3 – gate moving; 4 – gate sealing (for closing).</p>
          </caption>
          <graphic xlink:href="nucet-07-e78339-g003.jpg" position="float" orientation="portrait" xlink:type="simple" id="oo_624488.jpg">
            <uri content-type="original_file">https://binary.pensoft.net/fig/624488</uri>
          </graphic>
        </fig>
        <p>A distinctive feature of this approach is that segmentation is fully automatic and uses a pretrained neural network of the U-Time type (<xref ref-type="bibr" rid="B12">Perslev et al. 2019</xref>) (a convolution network adapted for segmentation of time series and built based on the encoder/decoder principle using skip-connections, that is, components which connect the decoder and encoder parts in each scale). Such description of the network architecture and the evidences to prove its efficiency as applied to segmentation of the active power signal are presented in (<xref ref-type="bibr" rid="B7">Kotsoyev et al. 2021</xref>).</p>
        <p>For each time point of the active power cyclogram, the neural network predicts the probability of any given segment. Therefore, one can state after a set of the active power cyclogram points is selected, the probability of a segment for which is close to unity (e.g., of over 0.95), that these points relate to the selected segment and define its boundaries (Fig. <xref ref-type="fig" rid="F4">4</xref>).</p>
        <fig id="F4" position="float" orientation="portrait">
          <object-id content-type="doi">10.3897/nucet.7.78339.figure4</object-id>
          <object-id content-type="arpha">8B1373F2-267A-51D2-96F5-54166D54B74D</object-id>
          <label>Figure 4.</label>
          <caption>
            <p>Result of the active power cyclogram segmentation. The probability of each segment <italic>p</italic> (segm. <italic>N</italic>), <italic>N</italic> ∈ [1, 4] has been obtained by a neural network.</p>
          </caption>
          <graphic xlink:href="nucet-07-e78339-g004.jpg" position="float" orientation="portrait" xlink:type="simple" id="oo_624489.jpg">
            <uri content-type="original_file">https://binary.pensoft.net/fig/624489</uri>
          </graphic>
        </fig>
        <p>The neural network is trained on a large array of MDV signals (cyclograms), not necessarily for any particular type of valves, both based on opening and closing signals, and on shutoff and control MDVs. The so trained neural network is capable to segment any “relatively similar” MDV signal.</p>
        <p>In the process of training, the entire array of training data is broken down into data properly, on which the training is based, (training sample) and data for checking the quality of the trained network operation (validation sample).</p>
        <p>As shown in (<xref ref-type="bibr" rid="B7">Kotsoyev et al. 2021</xref>), the network trained based on a training sample of 500 cyclograms identifies segments based on a validation sample (150 cyclograms) correctly in the following percentage ratios:</p>
        <list list-type="bullet">
          <list-item>
            <p>segment 1: 98.28%;</p>
          </list-item>
          <list-item>
            <p>segment 2: 92.60%;</p>
          </list-item>
          <list-item>
            <p>segment 3: 99.73%;</p>
          </list-item>
          <list-item>
            <p>segment 4: 71.65%.</p>
          </list-item>
        </list>
        <p>Therefore, the neural network training shall not necessarily be undertaken each time for each particular MDV. Training based on a large set of ‘similar’ data is enough, and it is also possible to use an earlier trained network. With an unsatisfactory quality of segmentation, the network should be trained additionally on the signals of the given MDV.</p>
      </sec>
      <sec sec-type="Identifying the set of diagnostic signs" id="SECID0EHBAC">
        <title>Identifying the set of diagnostic signs</title>
        <p>A set of diagnostic signs is identified for each segment. Information calculated based on current signals (by phases) and Fourier spectra from active power and current signals are used along with the active power signal.</p>
        <p>The results in (<xref ref-type="bibr" rid="B11">MT 1.2.3.02.999.0085-2010</xref>, <xref ref-type="bibr" rid="B2">Abidova et al. 2016b</xref>) were taken into account when determining the set of diagnostic signs.</p>
        <p>According to (<xref ref-type="bibr" rid="B11">MT 1.2.3.02.999.0085-2010</xref>), the following characteristics are extracted from the cyclogram in the process of the MDV diagnostics:</p>
        <list list-type="bullet">
          <list-item>
            <p>opening (closing) operation runtime, s;</p>
          </list-item>
          <list-item>
            <p>difference in the opening and closing time, absolute (sec) and relative (%);</p>
          </list-item>
          <list-item>
            <p>opening (closing) gate moving current, A;</p>
          </list-item>
          <list-item>
            <p>opening (closing) gate moving power, kW;</p>
          </list-item>
          <list-item>
            <p>opening (closing) gate moving time, s;</p>
          </list-item>
          <list-item>
            <p>ratio of the startup current value to the working current value (the startup power value to the working power value) in the opening (closing) moving;</p>
          </list-item>
          <list-item>
            <p>ratio of the gate shift current (power) to the working current (power) in the course of the opening operation;</p>
          </list-item>
          <list-item>
            <p>ratio of the gate sealing current (power) to the working current (power) in the course of the closing operation;</p>
          </list-item>
          <list-item>
            <p>gate shift smoothness in terms of the current signal (active power signal) during opening (closing);</p>
          </list-item>
          <list-item>
            <p>coefficient of divergence in the current (active power) values in the limits of the opening and closing operation runtime boundaries;</p>
          </list-item>
          <list-item>
            <p>motor startup time interval, s;</p>
          </list-item>
          <list-item>
            <p>shutoff gate sealing time during closing, s;</p>
          </list-item>
          <list-item>
            <p>motor shutdown time at the opening and closing operation end, s;</p>
          </list-item>
          <list-item>
            <p>shutoff valve gate shift time during opening operation, s;</p>
          </list-item>
          <list-item>
            <p>working current (voltage) asymmetry in phases A, B and C;</p>
          </list-item>
          <list-item>
            <p>amplitude of the harmonic matching the motor output shaft speed.</p>
          </list-item>
        </list>
        <p>The above diagnostic signs are identified by segments (its own set of diagnostic signs is prepared for each segment).</p>
        <p>Stochastic characteristics of cyclograms (such as entropy) were investigated in (<xref ref-type="bibr" rid="B2">Abidova et al. 2016b</xref>) depending on the extent of the defect manifestation. The connection of Shannon entropy to the MDV state was shown theoretically in (<xref ref-type="bibr" rid="B2">Abidova et al. 2016b</xref>) and a higher sensitivity of Shannon entropy with respect to individual defect types was shown.</p>
        <p>In this connection, such characteristics as Shannon entropy and interchange entropy were selected as diagnostic signs (in addition to those listed above) (<xref ref-type="bibr" rid="B1">Abidova et al. 2016a</xref>).</p>
        <p>Both entropies characterize the variability of the process. Additional harmonics occur in the signal and the variability grows as the item condition deteriorates. The Shannon entropy increases and the interchange entropy decreases as the variability grows (<xref ref-type="bibr" rid="B5">Chumak 2011</xref>).</p>
        <p>A connection is shown in (<xref ref-type="bibr" rid="B6">Khegay 2017</xref>) between the entropy indicators and the nature of the MDV failure (electrical or mechanical component failure).</p>
        <p>The following diagnostic signs were calculated for each segment.</p>
        <p><bold>Segment 1</bold> (motor start and roll):</p>
        <list list-type="bullet">
          <list-item>
            <p>peak width at half height;</p>
          </list-item>
          <list-item>
            <p>segment maximum;</p>
          </list-item>
          <list-item>
            <p>sum of squared deviations from the rising edge linear regression.</p>
          </list-item>
        </list>
        <p><bold>Segment 2</bold> (shutoff valve gate shift, for opening):</p>
        <list list-type="bullet">
          <list-item>
            <p>peak width at half height;</p>
          </list-item>
          <list-item>
            <p>segment maximum.</p>
          </list-item>
        </list>
        <p><bold>Segment 3</bold> (damper movement):</p>
        <list list-type="bullet">
          <list-item>
            <p>average distance between the upper envelope and the lower envelope (for maximums and minimums) in terms of active power;</p>
          </list-item>
          <list-item>
            <p>spectral entropy;</p>
          </list-item>
          <list-item>
            <p>Shannon entropy;</p>
          </list-item>
          <list-item>
            <p>interchange entropy;</p>
          </list-item>
          <list-item>
            <p>working current value by phases;</p>
          </list-item>
          <list-item>
            <p>working current asymmetry;</p>
          </list-item>
          <list-item>
            <p>gate moving smoothness (for current) by phases (for envelope, Hilbert);</p>
          </list-item>
          <list-item>
            <p>current smoothness difference by phases;</p>
          </list-item>
          <list-item>
            <p>spectrum amplitude.</p>
          </list-item>
        </list>
        <p><bold>Segment 4</bold> (gate sealing, for closing):</p>
        <list list-type="bullet">
          <list-item>
            <p>segment maximum;</p>
          </list-item>
          <list-item>
            <p>slope angle (linear regression);</p>
          </list-item>
          <list-item>
            <p>sum of squared deviations from the segment linear regression;</p>
          </list-item>
          <list-item>
            <p>distance between the maximum and the minimum.</p>
          </list-item>
          <list-item>
            <p>Shared characteristics according to the cyclogram:</p>
          </list-item>
          <list-item>
            <p>ratio of startup power to gate moving power;</p>
          </list-item>
          <list-item>
            <p>ratio of crack power to gate moving power;</p>
          </list-item>
          <list-item>
            <p>ratio of gate sealing power to gate moving power;</p>
          </list-item>
          <list-item>
            <p>ratio of startup current to gate moving current;</p>
          </list-item>
          <list-item>
            <p>ratio of crack current to gate moving current;</p>
          </list-item>
          <list-item>
            <p>valve final action time;</p>
          </list-item>
          <list-item>
            <p>crack detector;</p>
          </list-item>
          <list-item>
            <p>gate sealing detector.</p>
          </list-item>
        </list>
        <p>This set of diagnostic signs is not final and may be changed by the operator (the operator is in a position to decide that any of the signs are insignificant for diagnostics of the given MDV or ‘switch’ them off).</p>
      </sec>
      <sec sec-type="Permissible boundaries of diagnostic signs" id="SECID0E5EAC">
        <title>Permissible boundaries of diagnostic signs</title>
        <p>With a database available for the particular MDV, the trained neural network segments each cyclogram and diagnostic signs are identified further by segments. Assuming that most opening and closing operations take place normally (there are no multiple critical failures and the valves are in operation on the whole), it becomes possible to determine the permissible intervals for each diagnostic sign based on the accumulated statistics (using 0.25-quantile <italic>Q</italic><sub>1</sub> and 0.75-quantile <italic>Q</italic><sub>3</sub>, Fig. <xref ref-type="fig" rid="F5">5</xref>). Single ‘defective’ actuations are screened off automatically.</p>
        <fig id="F5" position="float" orientation="portrait">
          <object-id content-type="doi">10.3897/nucet.7.78339.figure5</object-id>
          <object-id content-type="arpha">C85D60F6-94B7-5382-BB4A-A8D0104E4A05</object-id>
          <label>Figure 5.</label>
          <caption>
            <p>Quantiles of distribution obtained for each diagnostic sign.</p>
          </caption>
          <graphic xlink:href="nucet-07-e78339-g005.jpg" position="float" orientation="portrait" xlink:type="simple" id="oo_624490.jpg">
            <uri content-type="original_file">https://binary.pensoft.net/fig/624490</uri>
          </graphic>
        </fig>
        <p>The diagnostic system includes a manual mode of defining tolerances for diagnostic signs which is important with no sufficient statistical data when these boundaries are fixed in the MDV datasheet. The operator is in a position to define the permissible intervals manually and then choose the operating mode: statistics alone, statistics with manual limits, or manual limits alone (e.g., the valves are new and there is no statistics so far).</p>
        <p>The cyclograms, the diagnostic signs for which are beyond the permissible intervals, are identified as a ‘defect’.</p>
        <p>An example of determining the permissible intervals based on statistics is given in Fig. <xref ref-type="fig" rid="F6">6</xref> for the diagnostic sign “gate moving smoothness for phase <italic>С</italic>”. The diagnostic sign “gate moving smoothness”, γ, is calculated for segment 3 as</p>
        <p><mml:math id="M2"><mml:mi>γ</mml:mi><mml:mo>=</mml:mo><mml:mfenced><mml:mrow><mml:mn>1</mml:mn><mml:mo>-</mml:mo><mml:mfrac><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi>max</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>I</mml:mi><mml:mi>min</mml:mi></mml:msub></mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mrow><mml:mi>m</mml:mi><mml:mi>e</mml:mi><mml:mi>d</mml:mi></mml:mrow></mml:msub></mml:mfrac></mml:mrow></mml:mfenced><mml:mo>·</mml:mo><mml:mn>100</mml:mn><mml:mo>%</mml:mo></mml:math>, (2)</p>
        <p>where <italic>I</italic><sub>max</sub>, <italic>I</italic><sub>min</sub>, <italic>I<sub>med</sub></italic> are the greatest, the smallest and the median values of the signal current envelope.</p>
        <p>According to (<xref ref-type="bibr" rid="B11">MT 1.2.3.02.999.0085-2010</xref>), value γ of below 75% is treated as a fault condition.</p>
        <fig id="F6" position="float" orientation="portrait">
          <object-id content-type="doi">10.3897/nucet.7.78339.figure6</object-id>
          <object-id content-type="arpha">01395A48-7B7D-55F4-8F5A-33A126DDF4A2</object-id>
          <label>Figure 6.</label>
          <caption>
            <p>Diagnostic sign “gate moving smoothness for phase <italic>С</italic>”: a) – histogram, <italic>x</italic><sub>0</sub> = 75.32 and <italic>x</italic><sub>1</sub> = 88.06 – left-hand and right-hand permissible boundaries for quantiles; b) – diagnostic sign value based on the closing cycle statistics for one and the same MDV.</p>
          </caption>
          <graphic xlink:href="nucet-07-e78339-g006.jpg" position="float" orientation="portrait" xlink:type="simple" id="oo_624491.jpg">
            <uri content-type="original_file">https://binary.pensoft.net/fig/624491</uri>
          </graphic>
        </fig>
      </sec>
      <sec sec-type="Cyclogram analysis and diagnosis generation" id="SECID0ECHAC">
        <title>Cyclogram analysis and diagnosis generation</title>
        <p>After the permissible intervals are determined for diagnostic signs, the diagnostic system is capable to generate the diagnosis for each particular cyclogram.</p>
        <p>Diagnosis is made in accordance with Appendix P to Methodology (<xref ref-type="bibr" rid="B11">MT 1.2.3.02.999.0085-2010</xref>). The appendix lists the potential defects for each MDV component and describes how the defect manifests itself through the cyclogram characteristics.</p>
        <p>The neural system segments the cyclogram obtained and identifies the diagnostic signs by segments. If all of the identified signs are within the permissible intervals, such signal is defined as “normal”. If one or more signs are outside the permissible limits, the “failure” is detected and the identified failure and the potential MDV defect are compared in accordance with (<xref ref-type="bibr" rid="B11">MT 1.2.3.02.999.0085-2010</xref>) (Table <xref ref-type="table" rid="T1">1</xref>).</p>
        <p>Taking into account that several signs can simultaneously indicate to the same failure (e.g., being simultaneously outside the permissible boundaries are the following signs for segment 3: “working current asymmetry”, “gate moving smoothness (in terms of current) for phases (for envelope, Hilbert)”, “spectrum amplitude”, or for segment 4: “segment maximum”, “distance between maximum and minimum”, which indicate the same defect (“No sufficient lubricant or lubricant contamination in the motor drive gear box”), the notion of defect “repeatability” was introduced. The defect repeatability is the higher, the larger is the number of signs which indicate the given defect (among the overall number of signs being outside the permissible limits).</p>
        <p>An example of the diagnostic system display is given in Table <xref ref-type="table" rid="T2">2</xref>.</p>
        <table-wrap id="T1" position="float" orientation="portrait">
          <label>Table 1.</label>
          <caption>
            <p>Example of comparing the cyclogram characteristics and diagnostic signs</p>
          </caption>
          <table id="TID0EHOAE" rules="all">
            <tbody>
              <tr>
                <th rowspan="1" colspan="1">Defect</th>
                <th rowspan="1" colspan="1">Manifestation in cyclogram</th>
                <th rowspan="1" colspan="1">Diagnostic signs</th>
              </tr>
              <tr>
                <td rowspan="2" colspan="1">Motor output shaft beat</td>
                <td rowspan="1" colspan="1">Opening/closing takes more time than rated</td>
                <td rowspan="1" colspan="1"><bold>Shared characteristics</bold> according to cyclogram: valve final action time</td>
              </tr>
              <tr>
                <td rowspan="1" colspan="1">Gate moving smoothness less than normal (equal in all three phases)</td>
                <td rowspan="1" colspan="1"><bold>Segment 3</bold>: gate moving smoothness (in terms of current) for phases (for envelope, Hilbert); current smoothness difference for phases</td>
              </tr>
              <tr>
                <td rowspan="5" colspan="1">No sufficient lubricant or lubricant contamination in the motor drive gear box</td>
                <td rowspan="1" colspan="1">Gate moving smoothness less than normal (equal in all three phases)</td>
                <td rowspan="2" colspan="1"><bold>Segment 3</bold>: working current asymmetry; gate moving smoothness (in terms of current) for phases (for envelope, Hilbert); spectrum amplitude</td>
              </tr>
              <tr>
                <td rowspan="1" colspan="1">High torque during valve closing</td>
              </tr>
              <tr>
                <td rowspan="1" colspan="1">Startup current much in excess of working current</td>
                <td rowspan="1" colspan="1"><bold>Shared characteristics</bold> according to cyclorgam: ratio of startup current to gate moving current; valve final action time</td>
              </tr>
              <tr>
                <td rowspan="1" colspan="1">Opening/closing takes more time than rated</td>
                <td rowspan="2" colspan="1"><bold>Segment 4</bold>: segment maximum; distance between maximum and minimum</td>
              </tr>
              <tr>
                <td rowspan="1" colspan="1">Motor high-load operation</td>
              </tr>
              <tr>
                <td rowspan="1" colspan="1">Motor winding damage (defects)</td>
                <td rowspan="1" colspan="1">Working current and voltage asymmetry in phases (phase unbalance over 10%)</td>
                <td rowspan="1" colspan="1"><bold>Segment 3</bold>: working current asymmetry</td>
              </tr>
              <tr>
                <td rowspan="4" colspan="1">Motor malfunctions</td>
                <td rowspan="1" colspan="1">Startup current much in excess of working current</td>
                <td rowspan="2" colspan="1"><bold>Segment 1</bold>: peak width at half height; segment maximum; sum of squared deviations from rising edge linear regression</td>
              </tr>
              <tr>
                <td rowspan="1" colspan="1">Long motor starting time</td>
              </tr>
              <tr>
                <td rowspan="1" colspan="1">Working current greater than rated</td>
                <td rowspan="1" colspan="1"><bold>Segment 3</bold>: working current value for phases</td>
              </tr>
              <tr>
                <td rowspan="1" colspan="1">Opening/closing takes more time than rated</td>
                <td rowspan="1" colspan="1"><bold>Shared characteristics</bold> according to cyclogram: ratio of startup current to gate moving current; valve final action time</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
        <table-wrap id="T2" position="float" orientation="portrait">
          <label>Table 2.</label>
          <caption>
            <p>Example of diagnosis for a signal cyclogram</p>
          </caption>
          <table id="TID0EOUAE" rules="all">
            <tbody>
              <tr>
                <th rowspan="1" colspan="1">Failure</th>
                <th rowspan="1" colspan="1">Repeatability</th>
              </tr>
              <tr>
                <td rowspan="1" colspan="1">One-sided wear in MD worm gear pair</td>
                <td rowspan="1" colspan="1">25.00%</td>
              </tr>
              <tr>
                <td rowspan="1" colspan="1">No sufficient lubricant or lubricant contamination in MD gear box</td>
                <td rowspan="1" colspan="1">25.00%</td>
              </tr>
              <tr>
                <td rowspan="1" colspan="1">Motor output shaft beat</td>
                <td rowspan="1" colspan="1">18.75%</td>
              </tr>
              <tr>
                <td rowspan="1" colspan="1">Wear of the gear box kinematic pairs, teeth breakdown in MD gear assemblies</td>
                <td rowspan="1" colspan="1">18.75%</td>
              </tr>
              <tr>
                <td rowspan="1" colspan="1">Increased “waviness” of active power. Deviation from the value typical of given valve</td>
                <td rowspan="1" colspan="1">6.25%</td>
              </tr>
              <tr>
                <td rowspan="1" colspan="1">Motor stator winding fault</td>
                <td rowspan="1" colspan="1">6.25%</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
      </sec>
    </sec>
    <sec sec-type="Conclusions" id="SECID0EVHAC">
      <title>Conclusions</title>
      <p>A prototype of the automated MDV failure detection system has been developed and deployed.</p>
      <p>The developed system allows rapid online diagnostics of the MDV operation which increases greatly the probability of defects to be detected at early stages without waiting for critical failures, to make it possible to update the equipment repair schedules and reduce the repair costs, and to avoid sudden breakdown of equipment.</p>
      <p>The system allows flexibility of adjustment for the given MDV type, and makes it possible to take into account both rated limits for the valve parameters and the fluid effects in the NPP piping. The operator can define his/her own set of diagnostic signs which describe as fully and accurately as possible the operation of the given MDV.</p>
      <p>Automation of the segmentation process excludes the human factor effects and makes it possible to analyze the statistics of the MDV actuations, find trends in the diagnostic sign changes and predict the deterioration in the valve condition.</p>
      <p>The aforesaid allows increasing greatly the reliability of the MDV failure detection and making the diagnostics fuller and more target-focused.</p>
      <p>As a result of testing the operation of the developed diagnostic system, the listed valve failures coincided with the listed malfunctions identified as part of the offline diagnostics for the Integrated Valve Diagnostic System installed at unit 6 of the Novovoronezh NPP.</p>
    </sec>
  </body>
  <back>
    <ref-list>
      <title>References</title>
      <ref id="B1">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Abidova</surname><given-names>YeA</given-names></name><name name-style="western"><surname>Khegay</surname><given-names>LS</given-names></name><name name-style="western"><surname>Chernov</surname><given-names>AV</given-names></name><name name-style="western"><surname>Bulava</surname><given-names>VA</given-names></name><name name-style="western"><surname>Solovyev</surname><given-names>VI</given-names></name><name name-style="western"><surname>Pugacheva</surname><given-names>OYu</given-names></name></person-group> (<year>2016a</year>) <article-title>Diagnostics of diesel generator equipment at nuclear power plants using deterministic and stochastic methods.</article-title><source>Globalnaya yadernaya bezopasnost</source><volume>3</volume>(<issue>20</issue>): <fpage>74</fpage>–<lpage>79</lpage>. <ext-link xlink:type="simple" ext-link-type="doi" xlink:href="10.26583/gns-2016-03-07">https://doi.org/10.26583/gns-2016-03-07</ext-link> [in Russian]</mixed-citation>
      </ref>
      <ref id="B2">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Abidova</surname><given-names>YeA</given-names></name><name name-style="western"><surname>Khegay</surname><given-names>LS</given-names></name><name name-style="western"><surname>Chernov</surname><given-names>AV</given-names></name><name name-style="western"><surname>Draka</surname><given-names>OYe</given-names></name><name name-style="western"><surname>Pugacheva</surname><given-names>OYu</given-names></name></person-group> (<year>2016b</year>) <article-title>Diagnostics of valves using entropy indicators.</article-title><source>Globalnaya yadernaya bezopasnost</source><volume>4</volume>(<issue>21</issue>): <fpage>69</fpage>–<lpage>77</lpage>. <ext-link xlink:type="simple" ext-link-type="doi" xlink:href="10.26583/gns-2016-04-09">https://doi.org/10.26583/gns-2016-04-09</ext-link> [in Russian]</mixed-citation>
      </ref>
      <ref id="B3">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Abidova</surname><given-names>YeA</given-names></name><name name-style="western"><surname>Malik</surname><given-names>OV</given-names></name><name name-style="western"><surname>Gavrilenko</surname><given-names>DS</given-names></name></person-group> (<year>2015</year>) <article-title>A system for processing motor-driven valve diagnostic signals.</article-title><source>Globalnaya yadernaya bezopasnost</source><volume>2</volume>(<issue>15</issue>): <fpage>56</fpage>–<lpage>62</lpage>. <ext-link xlink:type="simple" ext-link-type="doi" xlink:href="10.26583/npe.2015.3.06">https://doi.org/10.26583/npe.2015.3.06</ext-link> [in Russian]</mixed-citation>
      </ref>
      <ref id="B4">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Adamenkov</surname><given-names>AK</given-names></name></person-group> (<year>2009</year>) Diagnostic Support for the Transition to Maintenance and Repair of Shutoff and Control Valves at NPPs Based on Their Technical Condition. Cand. Sci. (Engineering) Diss. Abstr. Volgodonsk. VITI Publ., 26 pp. [in Russian]</mixed-citation>
      </ref>
      <ref id="B5">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Chumak</surname><given-names>OV</given-names></name></person-group> (<year>2011</year>) <source>Entropies and Fractals in Data Analysis. Moscow-Izhevsk.</source><publisher-name>NITs Regulyarnaya i khaoticheskaya dinamika Publ.</publisher-name>, <publisher-loc>Institute for Computer Studies</publisher-loc>, <size units="page">164 pp</size>. [in Russian]</mixed-citation>
      </ref>
      <ref id="B6">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Khegay</surname><given-names>LS</given-names></name></person-group> (<year>2017</year>) The Software and Hardware Complex of the Diagnostic System for the NPP Electromechanical Equipment Based on the Entropy Parameterization of Diagnostic Signals. Cand. Sci. (Engineering) Diss. Volgodonsk. VITI NIYaU MIFI Publ., 138 pp. [in Russian]</mixed-citation>
      </ref>
      <ref id="B7">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Kotsoyev</surname><given-names>KI</given-names></name><name name-style="western"><surname>Trykov</surname><given-names>YeL</given-names></name><name name-style="western"><surname>Trykova</surname><given-names>IV</given-names></name></person-group> (<year>2021</year>) <article-title>Using a convolutional neural network for segmentation of motor-driven valve signals. Izvestiya vuzov.</article-title><source>Yadernaya energetika</source><volume>2</volume>: <fpage>158</fpage>–<lpage>168</lpage>. <ext-link xlink:type="simple" ext-link-type="doi" xlink:href="10.26583/npe/2021.2.14">https://doi.org/10.26583/npe/2021.2.14</ext-link> [in Russian]</mixed-citation>
      </ref>
      <ref id="B8">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Matveyev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Skladnikov</surname><given-names>AF</given-names></name></person-group> (<year>2009a</year>) <article-title>Diagnostics of motor-driven valves using active power parameters.</article-title><source>Armaturostroyeniye</source><volume>3</volume>(<issue>60</issue>): <fpage>67</fpage>–<lpage>71</lpage>. <ext-link xlink:type="simple" ext-link-type="uri" xlink:href="https://docplayer.ru/74845967-Diagnostirovanie-armatury.html">https://docplayer.ru/74845967-Diagnostirovanie-armatury.html</ext-link> [accessed Feb. 20, 2021] [in Russian]</mixed-citation>
      </ref>
      <ref id="B9">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Matveyev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Skladnikov</surname><given-names>AF</given-names></name></person-group> (<year>2009b</year>) <article-title>Diagnostics of motor-driven valves using relative electrical parameters.</article-title><source>Armaturostroyeniye</source><volume>3</volume>(<issue>60</issue>): <fpage>40</fpage>–<lpage>51</lpage>. <ext-link xlink:type="simple" ext-link-type="uri" xlink:href="http://www.diaprom.com/publication/?id=5/">http://www.diaprom.com/publication/?id=5/</ext-link> [accessed Feb. 20, 2021] [in Russian]</mixed-citation>
      </ref>
      <ref id="B10">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Matveyev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Zhidkov</surname><given-names>SV</given-names></name><name name-style="western"><surname>Adamenkov</surname><given-names>AK</given-names></name><name name-style="western"><surname>Galivets</surname><given-names>YeYu</given-names></name><name name-style="western"><surname>Usanov</surname><given-names>DA</given-names></name></person-group> (<year>2009</year>) <article-title>An integrated approach to diagnosing motor-driven valves as applied to the lifetime management problems.</article-title><source>Armaturostroyeniye</source><volume>2</volume>(<issue>59</issue>): <fpage>53</fpage>–<lpage>59</lpage>. [in Russian]</mixed-citation>
      </ref>
      <ref id="B11">
        <mixed-citation xlink:type="simple"><institution>MT 1.2.3.02.999.0085-2010</institution> (<year>2010</year>) MT 1.2.3.02.999.0085-2010 Diagnostics of Motor-driven Pipeline Valves. Methodology. Put into effect by JSC Concern Rosenergoatom’s Order No. 9/270-17 (dated 27.03.2012). [in Russian]</mixed-citation>
      </ref>
      <ref id="B12">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Perslev</surname><given-names>M</given-names></name><name name-style="western"><surname>Jensen</surname><given-names>MH</given-names></name><name name-style="western"><surname>Darkner</surname><given-names>S</given-names></name><name name-style="western"><surname>Jennum</surname><given-names>PJ</given-names></name><name name-style="western"><surname>Igel</surname><given-names>C</given-names></name></person-group> (<year>2019</year>) U-Time: A Fully Convolutional Network for Time Series Segmentation Applied to Sleep Staging. arXiv: 1910.11162v1 [cs.LG], 19 pp.</mixed-citation>
      </ref>
      <ref id="B13">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Slepov</surname><given-names>MT</given-names></name><name name-style="western"><surname>Sysoyev</surname><given-names>NP</given-names></name></person-group> (<year>2014</year>) <article-title>Diagnostics of motor-driven valves: experience of the Novovoronezh NPP.</article-title><source>Globalnaya yadernaya bezopasnost</source><volume>2</volume>(<issue>11</issue>): <fpage>79</fpage>–<lpage>85</lpage>. [in Russian]</mixed-citation>
      </ref>
    </ref-list>
    <fn-group>
      <fn id="fntitle">
        <p>* Russian text published: Izvestiya vuzov. Yadernaya Energetika (ISSN 0204-3327), 2021, n. 3, pp. 72–83.</p>
      </fn>
    </fn-group>
  </back>
</article>