Parameter;"Variation range" "Initial integrated RC power, MW";±5% "Residual power, MW";±25% "The frequency of MCP-1 rotation, rpm";±3.75 "The frequency of MCP-2 rotation, rpm";±3.75 "Feedwater flow rate in SG, kg/s";±5.8 "Speed of CPS rods, cm/s";±5% "Feedwater temperature in SG, °С";±3.5 "Initial diameter of fuel pellets, mm";–0.15 "Multiplier applied to the wall heat transfer closure relation in SG from the water side or in AHE from the air side, rel. units";±30% "Multiplier applied to the wall friction closure relation in SG from the water side or in AHE from the air side, rel. units";±30% "Multiplier applied to the interfacial friction closure relation in SG for water, rel. units";±30% "Multiplier applied to the wall heat transfer closure relation in RC, IHE and SG from the sodium side, rel. units";±20% "Multiplier applied to the wall friction closure relation in RC, IHE and SG from the sodium side, rel. units";±10% "Thermal conductivity of fuel, W/m/K";±20% "Thermal conductivity of the gas gap in the fuel rod, W/m/K";±10%