Corresponding author: Aleksandr S. Chugunov (tchugunov@mail.ru)
Academic editor: Yury Kazansky
Baromembrane purification methods as part of liquid radioactive media processing complexes are increasingly included in the practice of radioactive waste management. The paper presents the results of a comparative study of the performance of commercially available hyper- and nanofiltration elements when a simulated solution is continuously phosphatized. The study revealed the influence of changes in the feed solution salinity on the permeability, working pressure in the brine chamber of the hyper- and nanofiltration apparatus and the permeate salinity. It is shown that, in a closed loop of liquid radioactive waste, the introduction of polyphosphates to stabilize the truly dissolved forms of multivalent metals on the ULP reverse-osmotic membrane leads, as expected, to a systematic performance degradation, first of all, in the membrane permeability at a fixed pressure in the apparatus. The permeate of the system with a nanofiltration membrane, VNF (Vontron NanoFiltration), contains a sufficiently high salt concentration indicating that sodium salts formed during complexation are removed from the circuit, thereby reducing the solution osmotic pressure which critically affects the yield of the purified solution. Thus, nanofiltration in combination with chelating agents can be an effective tool for fractionating components of radioactive solutions, ensuring the achievement of standard indicators for wastewater and biologically hazardous substances that are subject to permanent disposal.
A high degree of stability in operation at the lowest possible mass/dimensional characteristics and volumes of radioactive waste subject to permanent disposal is a matter-of-course requirement imposed on systems for processing liquid radioactive media. To the greatest extent, this criterion is met by continuous action systems based on precipitation techniques and hyperfiltration.
Methods based on precipitation of controlled impurities in the form of poorly soluble compounds have the highest selectivity but, at the same time, the most complicated organization.
Hyperfiltration, which is considered to be quite an effective method for reducing the volume of radioactive waste of complex and irregular compositions subject to controlled storage or conditioning (
an increased volume of waste subject to permanent disposal due to the inclusion in their composition of environmentally friendly substances: hydrocarbons, chlorides and sulfates of sodium, potassium, magnesium and calcium, which can be legally introduced into the regional hydrographic network; and
limited permissible brine salinity for the target components due to the need to maintain the process driving force proportional to the difference between the pump head and osmotic pressure determined by the total ion concentration.
Using processing techniques for separating the components of solutions to be processed according to the degree of biological hazard and environmental impact, it is possible to increase the operational stability of the entire system by distributing substances over the cleaning stages and solve the following main tasks of industrial water supply:
recycling of the main bulk of water;
removal from the production process of the bulk of technogenic pollution represented primarily by alkali metal salts used or formed in technological processes;
localization and concentration of biologically hazardous components represented in most cases by salts of non-ferrous metals and activated corrosion products with subsequent removal of the resulting solutions for processing by precipitation methods; and
increased filling of 134,137Cs sorbents by reducing the competition for sorption sites from the side of polyvalent cations.
The use of nanofiltration elements seems to be the most promising for fractionating technogenic water components into groups with similar chemical properties. Unlike hyperfiltration (reverse osmosis) membranes, the selectivity of nanofiltration membranes is determined by the properties of salts contained in the solution: minimum (40–70%) for salts of alkali metals and maximum (90–95%) for salts of polyvalent metals (
Even 95% selectivity means a guaranteed transition of a part of ions of polyvalent metals, including activated products of corrosion and fission, to the permeate. Therefore, it seems reasonable to exclude the very probability of their transfer due to a sharp increase in the size of molecules, including ions of polyvalent metals, which can be realized by forming their complexes with large-sized ligands.
The aim of the work was to conduct a comparative study of the efficiency of technologies for processing radioactively contaminated solutions based on commercially available hyper- and nanofiltration apparatus, under conditions where the transfer of polyvalent metals providing a form of radioactive waste acceptable for permanent disposal is completely eliminated and the bulk of technologically and radioactively contaminated water is involved in industrial circulation.
Experiments were conducted on the facility, a schematic diagram of which is shown in Fig.
Schematic diagram of the facility: 1 – microfilter; 2 – salt dissolver 3a – hyperfiltration apparatus; 3b – hyperfiltration (nanofiltration) apparatus; 4 – intermediate tank; 5 – control tank.
The first processing stage involved an SL-10’ fibrous polypropylene microfilter with the declared pore size of 1.0 µm, a salt dissolver for dosing the complexone, and a Vontron series 1812–100 hyperfiltration element. Tap water of the St. Petersburg network was used as a feed solution supplied to the microfilter inlet with a permissible pressure of 0.32 ± 0.02 MPa for the element stable operation in low-pressure hyperfiltration mode. The permeate was collected in the feed tank of the final stage, and the concentrate in the intermediate tank equipped with an overflow device to maintain a constant level of the feed solution, from where it was transferred by gravity to the feed tank of the second stage.
The second stage was a circuit for concentrating biologically hazardous components, including:
a receiving-feeding tank;
a feeding membrane DLX pump with a capacity of 15 dm 3/h at a pressure up to 0.55 MPa;
a salt dissolver for continuous dosing of ligands; and
a microfilter to protect the membrane surface from potential mechanical effects of dispersed particles formed in the process.
For comparative studies at the second processing stage, structurally identical “Vontron” 1812-50 membrane elements with a membrane surface of 0.32 m2 were used, namely, hyperfiltration ULP and nanofiltration VNF.
The permeate at this step was discharged into the receiving tank of the final stage, ensuring the production of pure water for internal requirements and the concentrate discharged as waste water. The separating element was the “Vontron” 1812-50 hyperfiltration element.
The ratios of permeate and concentrate flows and the working pressure in the purge chamber were provided by drainage controllers with the required flow rate. At the second cleaning stage, an overflow valve is additionally installed with a response pressure of 0.5 MPa, which protects the feeding pump from overloading.
Changes in total salt concentrations in the flows were promptly monitored by conductometric salinometers (DM1 Dual In-line TDS Meters).
To control the total hardness and concentration of the permeate components, well-known methods were used (
Table
Indicators of the solution in the circulation circuit during the transition to stationary mode.
Indicator | System water | Second step feed solution |
---|---|---|
TDS-meter salt content, mg/dm3 | 31 | 72 |
рН | 6.85 | 6.82 |
Na+, mg/dm3 | 7 | 14 |
Total alkalinity, mEq/dm3 | 0.85 | 2.2 |
Total hardness, mEq/dm3 | 0.68 | 1.75 |
Са2+, mg/dm3 | 12 | 25 |
Mn2+, mg/dm3 | 0.09 | 0.24 |
Fe(II)+ Fe(III), mg/dm3 | 0.25 | 0.11 |
Co2+, mg/dm3 | BLD | BLD |
Ni2+, mg/dm3 | BLD | 0.03 |
Cu2+, mg/dm3 | BLD | 0.02 |
Zn2+, mg/dm3 | BLD | BLD |
Cl–, mg/dm3 | 17 | 16 |
NO3–, mg/dm3 | 0.4 | 1.4 |
Note: BLD – Below limit of detection
Theoretically, hyperfiltration from technogenic waters with such salinity makes it possible to extract ~95–98% of sufficiently pure water that is easily conditioned to almost any required standards. However, in the process of flow-through concentration, there is a high probability of spontaneous release of oxyhydrates, first of all Fe(III), and carbonates of alkaline-earth and non-ferrous metals within the apparatus and on the membrane surfaces. It should be noted that these metals are carriers, with which their radioactive chemical analogues are released, i.e., activated corrosion products (first of all 60Со) and some fission products (90Sr). This decreases the permissible reduction of radioactive solutions processed.
Nanofiltration elements as a kind of “molecular sieves” have a significantly lower selectivity for simple ionic salt forms than hyperfiltration membranes. This makes it possible to separate the components present in the solution and control the process by changing the size of the molecules when various complex forms with polyvalent cations are generated. This can be ensured through the use of complexones. It should be noted that the use of organic complexones, such as EDTA ions, has a number of negative aspects. For example, the relatively high solubility of these compounds (
Stability constants (lg
Central atom | Ligands | ||
---|---|---|---|
Pyrophosphate- | Tripolyphosphate- | Tetrapolyphosphate- | |
Mg2+ | 7.2 | 8.6 | 6.04 |
Ca2+ | 6.8 | 8.1 | 5.46 |
Mn2+ | 7.15 | ||
Co2+ | 6.1 | 6.94 | |
Ni2+ | 5.94 | 6.75 | |
Cu2+ | 7.6 | 8.3 | 9.44 |
Zn2+ | 8.7 | 7.5 |
Conversion of polyphosphates into practically insoluble orthophosphates fully compatible with cement matrices can be carried out, if necessary, by thermohydrolysis while, for the destruction of organic phosphates, it will be necessary to use rather complex and expensive systems of oxidative hydrolysis, for example, proposed for processing accumulated waste bottoms at nuclear power plants.
As Figure
Distribution of complex calcium tripolyphosphate forms.
Dosing of complexing substances (the so-called antiscalants) is widely used as a method for preventing the formation of deposits in hyperfiltration technologies for obtaining pure water.
For phosphating the solution at this stage, polyphosphate loading for household water softeners BF (TU 3697-023-48981941-2014) was used, the low dissolution rate of which allowed the use of simple ligand dispensers, i.e., salt dissolvers, thus increasing the entire system reliability.
Another advantage to be considered when using these compounds for processing technogenic waters is that the products of their hydrolysis are orthophosphate ions that, with Ca2+ and d-metal cations, form poorly soluble salts compatible with all mineral binders recommended for conditioning radioactive wastes. It is advisable to use lime “milk” as an alkaline agent and industrially manufactured equipment, for example, apparatus with a “jacket” and a mixing device.
Therefore, the most promising membrane methods for processing technologically and radioactively contaminated waters are systems with recycled feed solutions that make it possible as follows:
to reduce the number of installed baromembrane devices;
to stabilize soluble forms by binding polyvalent metal ions into stable complex compounds, ensuring the possibility of achieving a high degree of supersaturation of the solution during the permeate discharge;
to ensure that crystalline double salts are extracted from the supersaturated solution;
to remove the concentration polarization and reduce the probability of forming deposits due to a high solution rate maintained in the brine chamber; and
to effectively protect the membrane working layer against abrasion by dispersed particles using preliminary micro- or ultrafiltration.
Since the permeability of the salt-holding membranes and the quality of the filtrate is determined by the difference between the osmotic pressure π calculated by the Van Hoff equation
(where
Figures
Changes in the membrane permeability (
Changes in the brine chamber working pressure (
Changes in the permeate salinity (
The behavior of the hyperfiltration element under the considered conditions fully fits into the framework of the existing ideas (
The high membrane selectivity to ionic impurities leads to systematic accumulation of all components in the solution feeding the membrane apparatus, thus reducing the filtration driving force and the membrane permeability. With a constant flow of the solution entering the apparatus, this leads to an increase in the load on the controller, which causes an increase in the brine chamber pressure, partially compensating for the changed osmotic pressure effects. The result is a smooth decrease in the membrane permeability in the process of treating technogenic waters with the accumulation of soluble components.
It can be assumed that, in this salt concentration range, the membrane selectivity is constant. Consequently, the accumulation of alkali metal salts in the circulating solution leads to an increase in the rate of ion mass transfer through the separating membrane, which, at sufficiently high concentrations of electrolytes, begins to slow down the permeability decrease rate (see Fig.
In this regard, the introduction of complexonates to stabilize the condition of alkaline-earth and non-ferrous metals will necessarily lead to a performance degradation in the treatment process. Thus, the reaction of complex formation with polyphosphate ions and other complexones takes place in an equimolar ratio and can be represented by the net equation
Mez+ + Na2L → MeL + 2Na+.
Thus, the binding of one mole of osmotically active doubly and triply charged cations leads to the formation of three moles of osmotically active particles and, therefore, a threefold increase in osmotic pressure.
Other trends are observed in a system with a nanofiltration membrane. Salt concentrations in the permeate of these devices significantly exceed this figure not only for hyperfiltration but also for the feed solution at this processing stage. This indicates that sodium salts formed during complexation are removed from the concentrate. Thus, osmotically active particles are predominantly complexonates, in relation to which the hyperfiltration membrane exhibits semi-permeable properties.
In the permeates of the systems studied, analytically significant concentrations of alkaline-earth and non-ferrous metals were not observed: this is indicative of complex compounds formed in the solution. In relation to these compounds, the nanofiltration membrane has a high (not less than 99.9%) selectivity with practically insignificant retention potential for alkali metal salts. Obviously, during the processing of radioactive solutions, the concentrate discharged from this processing stage must contain 134,137Cs radionuclides. Methods for deep purification of alkali metal salt solutions from these compounds are well known and technically developed (
Thus, the nanofiltration unit is able to provide conditions for minimizing the amount of radioactive waste subject to permanent disposal.
To install the third purification stage for obtaining water with a quality exceeding the quality determined by GOST 6709-72 for distilled water is advisable only to obtain high-purity water. At a pressure of 0.5 MPa, the degree of conversion of the solution dispensed from the separation unit was 85–90%, with a membrane selectivity of at least 99.8%. In this case, a tenfold increase in specific activity of 137Cs to be discharged to the concentrate hydrographic network will be observed. To ensure the regulatory requirements, it is advisable to direct this solution to the filter-guarantor of the nanofiltration apparatus.
The obtained data show that, using systems based on industrially manufactured nanofiltration apparatus in combination with widely available and fairly inexpensive complexones, it is possible to solve the main problem of ensuring their deep purification, i.e., fractionation of liquid radioactive waste. The availability of an industrially developed element base could significantly contribute to the creation of cost-effective and environmentally friendly systems for processing technologically and radioactively contaminated waters, including those containing technogenic and natural ligands that complicate the organization of sorption purification systems (
The results were obtained in the implementation of the Draft State Task of the Ministry of Education and Science of the Russian Federation in the field of scientific activity No. 13.6572.2017/8.9.
* Russian text published: Izvestiya vuzov. Yadernaya Energetika (ISSN 0204-3327), 2019, n. 1, pp. 51–60.