Acoustic leak control systems (for instance, SAKT) are used at present for controlling leak tightness of equipment and pipelines, as well as for detecting in timely manner coolant leaks from the primary cooling circuit of nuclear reactor installations (NRI) during operation of power unit on different power levels in the modes of normal operation and during disturbances of normal operation. Time averaged dispersion of acoustic signal is used as the main diagnostic indicator for detecting leaks in these systems. Sensitivity of this indicator is determined by the exceedance by the signal of the preset threshold value which is defined in accordance with the background. Here, background values of acoustic signal depend on the operational modes of the equipment and do not allow in many cases determining coolant leak during early stages of leak development.
New approach to the formation of diagnostic indicators for detecting loss of sealing in the circuit during early stage of development of coolant leak is suggested.
Methodology for obtaining diagnostic indicators is based on the processing in different frequency bands of acoustic signal accompanying coolant leakage from the pipeline using the method of principal components.
Efficiency of the developed methodology of coolant leak detection is illustrated by processing acoustic signals for experimental facility modeling coolant leakage in case of loss of sealing of the circuit.
Even in the presence of significant acoustic background sensitivity of the method allows detecting leaks with significantly lower flow rates (up to five times smaller) than the conventional processing of acoustic signals.
Implementation of the developed methodology will not require significant expenditures for upgrading already existing leak control systems operated at present on different NPPs.
Acoustic leak control systems (SAKT in Russian abbreviation) are used at present for controlling leak tightness of equipment and pipelines, as well as for detecting in timely manner coolant leaks from the primary cooling circuit of nuclear reactor installations (NRI) during operation of power unit on different power levels in the modes of normal operation and during disturbances of normal operation (
Additional diagnostic indicators and methods for their identification allowing more reliably determining presence of leakages in the case of small coolant leakage flow rates are examined in the present paper. Pattern identification theory (
Measurements were conducted on the experimental stand imitating circulation loop at the INPE NRNU MEPhI designed for implementation of studies of acoustic noises and hydraulic characteristics of circulating coolants.
The experimental facility consists of the device for imitation of leak with compressed air and the simulator of heat exchange pipe intended for investigation of the nature of propagation of surface waves inside steel pipe. The simulator represents a pipe made of stainless steel 1X18H10T with length equal to 5000 mm and diameter equal to 45×3.5 mm. Acoustic emission sensor GT301 is fixed on one of the pipe’s ends.
Nozzle with calibrated aperture arranged on the pipe as part of the special tool acts as the transmitter of stress waves (leak imitator). Noise emitted during gas discharge from the nozzle imitates the noise of water leakage. Gas supply system consists of pressurized gas cylinder, gas pressure regulator, measuring volume, pressure gauge measuring gas pressure inside the measuring volume and the system of valves and nozzle.
Procedure for calibration of gas flow channel consists of the measurement of the value of gas pressure imitating the working medium.
Measuring volume
where
Let us note that the above formula is valid only for the subcritical gas discharge i.e. for the value
Dependences of the value of pressure in the measuring volume and gas flow rate on the time of gas discharge are presented in Figure
Time dependences of pressure and gas flow rate during gas discharge: 1 – pressure; 2 – flow rate.
Two integral statistical characteristics – acoustic wave spectrum power and average frequency of the spectrum – are usually applied for the detection of leaks during diagnostics of pipelines by acoustic method.
Spectrum power is equal to:
where
Average spectral frequency
is determined by the shape of frequency spectrum of the measured acoustic signal.
Application of the above diagnostic indicators is predetermined by the following facts:
Acoustic spectrum power increases with growing leakage;
Shape of acoustic spectrum changes when the leak emerges as compared with the background value (sharp shifting of the center of mass of the acoustic spectrum in the area of low frequencies takes place during the initial phase of leak initiation);
Implementation of estimation of the value and tentative location of the leakage source is possible using the correlation between quantitative characteristics, i.e. the diagnostic indicators, characterizing variation of power and shapes of spectra for sensors installed in different points.
Dispersions and average frequencies of acoustic signal of the sensor are presented in Figure
Average frequencies and dispersions of acoustic sensor signal within the frequency range from 100 kHz to 800 kHz.
Ratio of signal energies on different parts of the power spectrum, as well as the ratio of current average frequency to the average background frequency were selected as the diagnostic indicators in the suggested approach. Since signal within different frequency bands is attenuated differently, assumption was made that ratios of energies of signals within different frequency bands will be more informative diagnostic indicators than the total dispersion.
Signal energies within the frequency band from 100 kHz to 200 kHz (
It was necessary to normalize all indicators according to the same scale for the purpose of performing their analysis and to construct covariance matrix. In order to achieve the above the following formula was applied to each of the indicators:
where dispersion s and mathematical expectation m are calculated for the current time window.
Scaled indicators are shown in Figure
Normalized diagnostic indicators of the acoustic sensor at different time moments.
Let us construct covariance matrix for the indicators at
And, following this, calculate its eigenvalues which are, essentially, the dispersions of the indicators in the new space:
L
where L = diag(l1, l2, ..., l
For calculating covariance matrix all indicators
Comparison of variation of the largest eigenvalue of the covariance matrix (
Comparison of variation of the largest eigenvalue of covariance matrix (LEVCM) in time with signal dispersions (
Thus, indication of leak using LEVCM allows enhancing sensitivity of leak detection by more than two times. Results of leak indication are presented in Figure
The fact is of interest that LEVCM has sufficiently high value in the area of coolant flow rate where traditional diagnostic indicators (dispersion and average spectral frequency) already begin to attenuate exponentially. Therefore, it can be expected that in the presence of external noises (interferences) the method implying the use of LEVCM will demonstrate much higher sensitivity of leak detection than the conventional diagnostic indicators.
Tome evolution of the leak in the representation of principal components of the covariance matrix: triangles – conditions with absence of leak (vertex down – before initiation of the leak, vertex up – after leak attenuation); solid circles – conditions of leak at respective time moments.
The following test problem was solved for confirming this fact. White noise signal with dispersion equal to 1×10–2 V2 was added to the signal imitating the leak.
Comparison of variation of the largest eigenvalue of covariance matrix (LEVCM) with time with dispersions of signals and average spectral frequency is shown in Figs
Comparison of time variation of LEVCM with signal dispersions for the case when white noise signal is superimposed.
Comparison of time variation of LEVCM with average signal frequencies.
Practical application of the suggested approach in operable leak control systems can be implemented with employment of broadband acoustic sensors.
The suggested new approach allows enhancing sensitivity of leak control systems with regard to low-volume leaks although it requires experimental investigation of the case of real leaks of heated coolant.
In the case of presence of background noises sensitivity of the suggested method with respect to small leaks increases by up to five times as compared with conventional approach.
Implementation of the suggested approach will not require significant expenditures for upgrading existing leak control systems operated at present on different NPPs.