<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//TaxonX//DTD Taxonomic Treatment Publishing DTD v0 20100105//EN" "../../nlm/tax-treatment-NS0.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:tp="http://www.plazi.org/taxpub" article-type="research-article" dtd-version="3.0" xml:lang="en">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">79</journal-id>
      <journal-id journal-id-type="index">urn:lsid:arphahub.com:pub:D015427E-53F6-553C-9279-2E51CD684756</journal-id>
      <journal-title-group>
        <journal-title xml:lang="en">Nuclear Energy and Technology</journal-title>
        <abbrev-journal-title xml:lang="en">NUCET</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="epub">2452-3038</issn>
      <publisher>
        <publisher-name>National Research Nuclear University MEPhI (Moscow Engineering Physics Institute)</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.3897/nucet.4.29838</article-id>
      <article-id pub-id-type="publisher-id">29838</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Research Article</subject>
        </subj-group>
        <subj-group subj-group-type="scientific_subject">
          <subject>Heat transfer and Fluid dynamics</subject>
          <subject>Nuclear fuel and Reactor materials</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Measurement of the spent fuel rod cladding temperature during the in-pile testing at 500 – 900°C</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author" xlink:type="simple" corresp="yes">
          <name name-style="western">
            <surname>Dreganov</surname>
            <given-names>Oleg I.</given-names>
          </name>
          <xref ref-type="aff" rid="A1">1</xref>
          <email xlink:type="simple">sokratik9@yandex.ru</email>
        </contrib>
        <contrib contrib-type="author" xlink:type="simple" corresp="no">
          <name name-style="western">
            <surname>Shulimov</surname>
            <given-names>Vitalij N.</given-names>
          </name>
          <xref ref-type="aff" rid="A1">1</xref>
        </contrib>
        <contrib contrib-type="author" xlink:type="simple" corresp="no">
          <name name-style="western">
            <surname>Kiseleva</surname>
            <given-names>Irina V.</given-names>
          </name>
          <xref ref-type="aff" rid="A1">1</xref>
        </contrib>
        <contrib contrib-type="author" xlink:type="simple" corresp="no">
          <name name-style="western">
            <surname>Alekseev</surname>
            <given-names>Aleksandr V.</given-names>
          </name>
          <xref ref-type="aff" rid="A1">1</xref>
        </contrib>
      </contrib-group>
      <aff id="A1">
        <label>1</label>
        <addr-line content-type="verbatim">JSC “State Scientific Center – Research Institute of Atomic Reactors”, 9 Zapadnoye shosse, Dimitrovgrad, Ulyanovsk Reg., 433510, Russian Federation</addr-line>
        <institution>JSC “State Scientific Center – Research Institute of Atomic Reactors”</institution>
        <addr-line content-type="city">Dimitrovgrad</addr-line>
        <country>Russia</country>
      </aff>
      <author-notes>
        <fn fn-type="corresp">
          <p>Corresponding author: Oleg I. Dreganov (sokratik9@yandex.ru)</p>
        </fn>
        <fn fn-type="edited-by">
          <p>Academic editor: Yury Korovin</p>
        </fn>
      </author-notes>
      <pub-date pub-type="collection">
        <year>2018</year>
      </pub-date>
      <pub-date pub-type="epub">
        <day>17</day>
        <month>10</month>
        <year>2018</year>
      </pub-date>
      <volume>4</volume>
      <issue>1</issue>
      <fpage>21</fpage>
      <lpage>26</lpage>
      <uri content-type="arpha" xlink:href="http://openbiodiv.net/2BE2D292-ABC1-5E2A-9531-87D1B1AFE960">2BE2D292-ABC1-5E2A-9531-87D1B1AFE960</uri>
      <uri content-type="zenodo_dep_id" xlink:href="https://zenodo.org/record/2535158">2535158</uri>
      <history>
        <date date-type="received">
          <day>18</day>
          <month>09</month>
          <year>2018</year>
        </date>
        <date date-type="accepted">
          <day>19</day>
          <month>09</month>
          <year>2018</year>
        </date>
      </history>
      <permissions>
        <copyright-statement>Oleg I. Dreganov, Vitalij N. Shulimov, Irina V. Kiselyova, Aleksandr V. Alekseev</copyright-statement>
        <license license-type="creative-commons-attribution" xlink:href="http://creativecommons.org/licenses/by/4.0/" xlink:type="simple">
          <license-p>This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.</license-p>
        </license>
      </permissions>
      <abstract>
        <label>Abstract</label>
        <p>This paper deals with the problem of measuring the VVER-1000 burnup fuel cladding temperature in a 500–900°C range in the process of experiments in a channel of the MIR research reactor to obtain data on the fuel element behavior under the influence of the parameters typical of the maximum design-basis loss-of-coolant accident (<abbrev xlink:title="loss-of-coolant accident" id="ABBRID0EUD">LOCA</abbrev>). Studying the burnup fuel cladding deformation pattern requires measurements of the cladding temperature with no (thermal, mechanical and other) impacts on the cladding in the maximum deformation region.</p>
        <p>For dynamic experiments in the MIR reactor channel with fuel testing in a vapor-gas environment, a cladding temperature measuring unit has been developed, in which the cladding is not subjected to external impacts in the maximum deformation region. In the process of being installed into the spacer grid, the thermoelectric transducer (<abbrev xlink:title="thermoelectric transducer" id="ABBRID0E1D">TET</abbrev>) has its hot junction forced against the cladding making it possible to prevent the external impact on the cladding. The thermometric characteristic of the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0E5D">TET</abbrev> attachment, which is associated with the impact of the grid as such on its thermal condition, was studied using a laboratory facility. This technique was used in an in-pile experiment to study the fuel cladding deformation pattern.</p>
      </abstract>
      <kwd-group>
        <label>Keywords</label>
        <kwd>Laboratory facility (LF)</kwd>
        <kwd>experimental fuel element (EFE)</kwd>
        <kwd>electroheated fuel element simulator (EHFES)</kwd>
        <kwd>cladding</kwd>
        <kwd>spacer grid (SG)</kwd>
        <kwd>thermoelectric transducer (TET)</kwd>
        <kwd>hot junction</kwd>
        <kwd>temperature</kwd>
        <kwd>heat-up rate</kwd>
        <kwd>MIR reactor</kwd>
        <kwd>loss-of-coolant accident (LOCA).</kwd>
      </kwd-group>
    </article-meta>
    <notes>
      <sec sec-type="" id="SECID0EQE">
        <title/>
        <p>Nuclear Energy and Technology 4(1): 21–26</p>
      </sec>
      <sec sec-type="" id="SECID0EVE">
        <title/>
        <p>DOI <ext-link xlink:type="simple" ext-link-type="doi" xlink:href="10.3897/nucet.4.29838">10.3897/nucet.4.29838</ext-link></p>
      </sec>
    </notes>
  </front>
  <body>
    <sec sec-type="Introduction" id="SECID0EAF">
      <title>Introduction</title>
      <p>To study the behavior of the VVER-1000 reactor fuel elements during normal operation and anticipated operational occurrences, there is a whole class of reactor experiments (<xref ref-type="bibr" rid="B1">Alekseev et al. 2007a</xref>; <xref ref-type="bibr" rid="B8">Alekseev et al. 2006a</xref>, <xref ref-type="bibr" rid="B9">b</xref>; <xref ref-type="bibr" rid="B2">Alekseev et al. 2012</xref>), in which the item of interest shall be tested in a strictly defined temperature range. This is especially true in the event of a fuel element test in conditions of a loss-of-coolant accident (<abbrev xlink:title="loss-of-coolant accident" id="ABBRID0EWF">LOCA</abbrev>) (<xref ref-type="bibr" rid="B13">Goryachev et al. 2004</xref>, <xref ref-type="bibr" rid="B6">Alekseev et al. 2009</xref>, <xref ref-type="bibr" rid="B17">Salatov et al. 2013</xref>, <xref ref-type="bibr" rid="B13">Goryachev et al. 2004</xref>a), in which the cladding temperature varies in a temperature range of 700–900°C for different experiments with an accuracy of not more than 2–5%. If this value is exceeded, an additional factor may occur, which influences the property under investigation and <!--PageBreak-->cannot be taken into account in the interpretation of the experiment results.</p>
      <p>Such experiments require the cladding temperature to be known at any given time with such accuracy as is sufficient for the interpretation of the results.</p>
      <p>The temperature estimation in such experiments (<xref ref-type="bibr" rid="B19">Shulimov and Kiseleva 2004</xref>) does not lead to a successful result since the nonuniform power densities existing in the research reactor channel and the complexity of heat transfer in the vapor-gas environment the item is tested in under the <abbrev xlink:title="loss-of-coolant accident" id="ABBRID0ETG">LOCA</abbrev> conditions do not make it possible to achieve the acceptable calculation accuracy. The only way of temperature determination is online measurements. What is meant here is the measurement of the VVER-1000 burnup fuel cladding temperature since the testing of fresh fuel elements is of no practical interest.</p>
    </sec>
    <sec sec-type="methods" id="SECID0EXG">
      <title>Methods for the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0E3G">TET</abbrev> attachment to the burnup fuel cladding used in in-pile experiments</title>
      <p>Literature contains data on two ways to install a hot junction on the burnup fuel cladding: by means of remote spot welding performed in a shielded box (<xref ref-type="bibr" rid="B10">Askeljung et al. 2012</xref>) and using a special collar (Kekkonen Laura 2008) which is also installed remotely. The first of the methods was used for experiments in the Halden reactor channel, and the second technique for the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EGH">TET</abbrev> hot junction attachment was used in shielded-box experiments.</p>
      <p>The above-noted methods for the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EMH">TET</abbrev> attachment to the irradiated fuel cladding are used remotely and are hard to employ. Moreover, they may not be technologically feasible for some reactors. Certain problems occur when installing the communication lines between the sensor and the secondary transducer. For the channels of the MIR research reactor (Research Reactors of RIAR 1991), it is not technologically feasible due to the specific reactor design.</p>
      <p>If the list of the major properties to be studied includes the fuel cladding deformation pattern, then the attachment principle as such is an essential drawback of the said techniques because of the cladding subjected to mechanical and thermal impacts expected to affect the nature and the absolute magnitude of the deformation process.</p>
    </sec>
    <sec sec-type="Spent fuel cladding temperature measuring unit for experiments in the MIR reactor channel" id="SECID0ERH">
      <title>Spent fuel cladding temperature measuring unit for experiments in the MIR reactor channel</title>
      <p>For dynamic experiments in the MIR reactor channel (<xref ref-type="bibr" rid="B18">Shulimov et al. 2015</xref>; <xref ref-type="bibr" rid="B14">Izhutov et al. 2015</xref>; <xref ref-type="bibr" rid="B3">Alekseev et al. 2016</xref>; <xref ref-type="bibr" rid="B11">Goncharov et al. 2016</xref>; <xref ref-type="bibr" rid="B4">Alekseev et al. 2017a</xref>, <xref ref-type="bibr" rid="B5">b</xref>) where the item of interest is tested in a vapor-gas environment, a thermometric unit has been developed to measure the irradiated fuel cladding temperature, in which the cladding is not subjected to external impacts in the maximum deformation region. Such experiments include the VVER-100 fuel testing in the <abbrev xlink:title="loss-of-coolant accident" id="ABBRID0EQAAC">LOCA</abbrev> conditions.</p>
      <p>A distinctive feature of the developed technique consists in the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EWAAC">TET</abbrev> being installed into a spacer grid of a specific design such that the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0E1AAC">TET</abbrev> has its hot junction automatically forced against the fuel cladding when the spent fuel element is loaded remotely into the device. A major advantage of such attachment technique is that it does not require a remote operation in the process of the device assembly. The <abbrev xlink:title="thermoelectric transducer" id="ABBRID0E5AAC">TET</abbrev> and the communication lines between the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0ECBAC">TET</abbrev> and the secondary transducer are installed at the manufacturer’s assembly stand.</p>
      <p>Spacer grids (<abbrev xlink:title="spacer grid" id="ABBRID0EIBAC">SG</abbrev>) with a pitch of 200 mm were used to install the fuel element with the kernel length of 1000 mm into the device for the <abbrev xlink:title="loss-of-coolant accident" id="ABBRID0EMBAC">LOCA</abbrev> experiments. The <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EQBAC">TET</abbrev> hot junction position may be both inside of the <abbrev xlink:title="spacer grid" id="ABBRID0EUBAC">SG</abbrev> and at a distance of 5 to 7 mm from the <abbrev xlink:title="spacer grid" id="ABBRID0EYBAC">SG</abbrev> upper end. Both options require the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0E3BAC">TET</abbrev> hot junction to be forced against the fuel cladding by means of the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EACAC">TET</abbrev> attachment structure.</p>
    </sec>
    <sec sec-type="Laboratory facility to determine the thermometric characteristic of the TET attachment to the burnup fuel cladding" id="SECID0EECAC">
      <title>Laboratory facility to determine the thermometric characteristic of the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EJCAC">TET</abbrev> attachment to the burnup fuel cladding</title>
      <p>The extended surface of the <abbrev xlink:title="spacer grid" id="ABBRID0EPCAC">SG</abbrev> and a major loss of heat from this surface to the environment lead to the <abbrev xlink:title="spacer grid" id="ABBRID0ETCAC">SG</abbrev>’s substantial impact on the fuel cladding axial temperature distribution. This impact is especially marked in dynamic experiments. Without knowing the quantitative <abbrev xlink:title="spacer grid" id="ABBRID0EXCAC">SG</abbrev> impact on the cladding temperature distribution and the system of corrections for determining the cladding temperature between the grids, this method cannot be used to install the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0E2CAC">TET</abbrev> into the devices designed for experiments in the research reactor channels. It is obvious that the thermometric characteristics of the assembly with different <abbrev xlink:title="thermoelectric transducer" id="ABBRID0E6CAC">TET</abbrev> hot junction positions will differ from each other. Therefore, the corrections for the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EDDAC">TET</abbrev> readings in the <abbrev xlink:title="spacer grid" id="ABBRID0EHDAC">SG</abbrev> shall be determined separately for each option. These corrections were determined experimentally using a laboratory facility being a precise replica of the active part of the device for dynamic reactor experiments with simulation of the VVER-1000 <abbrev xlink:title="loss-of-coolant accident" id="ABBRID0ELDAC">LOCA</abbrev> parameters in the test channel. A fuel element simulator with an internal electric heater was used as the heat flux source in the facility.</p>
      <p>Fig. <xref ref-type="fig" rid="F1">1</xref> shows the overall view of the laboratory facility and the layout of its central part with the spacer grid (<abbrev xlink:title="spacer grid" id="ABBRID0EVDAC">SG</abbrev>) and <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EZDAC">TET</abbrev> locations. Inside of the device, electric heaters (EH) are installed on the side face of the shroud tube to create the external temperature conditions on the fuel element that are typical of operation in a multielement fuel assembly.</p>
      <p>In the central part of the laboratory facility (the volume with the <abbrev xlink:title="electroheated fuel element simulator" id="ABBRID0E6DAC">EHFES</abbrev>), the TETs are installed:</p>
      <!--PageBreak-->
      <p>– inside of three spacer grids (Т1, Т3, Т5) for the readings of which corrections are to be determined;</p>
      <p>– on the <abbrev xlink:title="electroheated fuel element simulator" id="ABBRID0EHEAC">EHFES</abbrev> cladding at three points at different heights (Т2, Т4, Т6) not connected to the <abbrev xlink:title="spacer grid" id="ABBRID0ELEAC">SG</abbrev>; the coordinates of the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EPEAC">TET</abbrev> hot junction attachment to the cladding are above the <abbrev xlink:title="spacer grid" id="ABBRID0ETEAC">SG</abbrev>;</p>
      <p>– on the shroud tubes and in the coolant.</p>
      <p>The <abbrev xlink:title="thermoelectric transducer" id="ABBRID0E1EAC">TET</abbrev> locations are shown in Fig. <xref ref-type="fig" rid="F1">1b</xref>. The <abbrev xlink:title="thermoelectric transducer" id="ABBRID0ECFAC">TET</abbrev> hot junction is at a distance of 5 to 7 mm from the <abbrev xlink:title="spacer grid" id="ABBRID0EGFAC">SG</abbrev>’s upper end in the upper spacer grid (<abbrev xlink:title="upper spacer grid" id="ABBRID0EKFAC">USG</abbrev>), and inside of the <abbrev xlink:title="spacer grid" id="ABBRID0EOFAC">SG</abbrev> in the central spacer grid (<abbrev xlink:title="central spacer grid" id="ABBRID0ESFAC">CSG</abbrev>) and in the lower spacer grid (<abbrev xlink:title="lower spacer grid" id="ABBRID0EWFAC">LSG</abbrev>).</p>
      <fig id="F1" position="float" orientation="portrait">
        <object-id content-type="doi">10.3897/nucet.4.29838.figure1</object-id>
        <object-id content-type="arpha">A6268728-C4CF-5AB0-86D9-C4BE172E7B31</object-id>
        <label>Figure 1.</label>
        <caption>
          <p>Laboratory facility: a) – overall view; b) – <abbrev xlink:title="spacer grid" id="ABBRID0ECGAC">SG</abbrev> and <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EGGAC">TET</abbrev> arrangement in the <abbrev xlink:title="laboratory facility" id="ABBRID0EKGAC">LF</abbrev></p>
        </caption>
        <graphic xlink:href="nucet-04-e29838-g001.jpg" position="float" orientation="portrait" xlink:type="simple" id="oo_236042.jpg">
          <uri content-type="original_file">https://binary.pensoft.net/fig/236042</uri>
        </graphic>
      </fig>
      <p>Wire binding was used for the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EUGAC">TET</abbrev> attachment to the <abbrev xlink:title="electroheated fuel element simulator" id="ABBRID0EYGAC">EHFES</abbrev> cladding. All TETs were connected to the information and measuring system (<abbrev xlink:title="information and measuring system" id="ABBRID0E3GAC">IMS</abbrev>) with a recording frequency of 1 Hz. For the temperature measurements both at the laboratory facility and in the reactor experiments, cable TETs (tolerance class 2.0) were used with a thermocouple of the chromel-alumel type (K-type), the steel (12Kh18N10T) shell diameter of 1.5 mm, a magnesium oxide insulation, and a joint hot junction of the thermocouple wires with a diameter of 0.27 mm. Before the experiments, all TETs were certified under GOST R 8.585–2001, for which the correction value is in a range of –0.7 to –1.5°C. For the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EAHAC">TET</abbrev> certification, the correction allowed for the thermoelectric nonuniformity, as well as for the communication between the temperature sensor and the secondary transducer (a signal converter). The <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EEHAC">TET</abbrev> time constant does not exceed 0.500 s.</p>
      <p>Fig. <xref ref-type="fig" rid="F2">2</xref> shows the points of the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EOHAC">TET</abbrev> attachment to the <abbrev xlink:title="electroheated fuel element simulator" id="ABBRID0ESHAC">EHFES</abbrev> cladding.</p>
    </sec>
    <sec sec-type="Experimental determination of corrections to the TET readings" id="SECID0EWHAC">
      <title>Experimental determination of corrections to the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0E2HAC">TET</abbrev> readings</title>
      <p>The values of the corrections for the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EBIAC">TET</abbrev> readings in the SGs (<italic>Т</italic><sub>2</sub> – <italic>Т</italic><sub>1</sub>, <italic>Т</italic><sub>4</sub> – <italic>Т</italic><sub>3</sub>, <italic>Т</italic><sub>6</sub> – <italic>Т</italic><sub>5</sub>) depend on the temperature of the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EXIAC">TET</abbrev> attachment and the value of the heat flow from the <abbrev xlink:title="electroheated fuel element simulator" id="ABBRID0E2IAC">EHFES</abbrev> cladding (cladding heat-up rate) in the <abbrev xlink:title="spacer grid" id="ABBRID0E6IAC">SG</abbrev> installation area. For this reason, the <abbrev xlink:title="electroheated fuel element simulator" id="ABBRID0EDJAC">EHFES</abbrev> power was varied during the experiment.</p>
      <p>We shall give the parameters of two <abbrev xlink:title="electroheated fuel element simulator" id="ABBRID0EJJAC">EHFES</abbrev> heat-up modes with the minimum and maximum heat-up rates as can be achieved using this equipment. Please note that the maximum heat-up rate corresponds to the value specified for the reactor experiment.</p>
      <p><bold>Mode 1</bold> – EHs 1 and 2 are on (each heater has a power of 350 W), the <abbrev xlink:title="electroheated fuel element simulator" id="ABBRID0ERJAC">EHFES</abbrev> power is increased in steps (16, 62, 135, 235, 377, 545 W).</p>
      <p><bold>Mode 2</bold> – EH 1 (340 W) and EH 2 (300 W) are on, stepwise <abbrev xlink:title="electroheated fuel element simulator" id="ABBRID0EZJAC">EHFES</abbrev> power increase in two steps of 790 and 900 W with intermediate cooling of the <abbrev xlink:title="electroheated fuel element simulator" id="ABBRID0E4JAC">EHFES</abbrev> cladding to 500°C.</p>
      <p>In each <abbrev xlink:title="electroheated fuel element simulator" id="ABBRID0EDKAC">EHFES</abbrev> heat-up mode, each further power increase step was preceded by a time delay for achieving a steady-state thermal condition.</p>
      <p>Table <xref ref-type="table" rid="T1">1</xref> shows values of the differences in the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0ENKAC">TET</abbrev> readings for each <abbrev xlink:title="spacer grid" id="ABBRID0ERKAC">SG</abbrev> and the rates of the growth in the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EVKAC">TET</abbrev> readings which are interconnected. Both parameters were determined in an on-line experiment.</p>
      <p>The spacer grid had the greatest effect on the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0E2KAC">TET</abbrev> readings with the hot junction being inside of the <abbrev xlink:title="spacer grid" id="ABBRID0E6KAC">SG</abbrev> (Fig. 2а), as was the case with the <abbrev xlink:title="lower spacer grid" id="ABBRID0EDLAC">LSG</abbrev> and the <abbrev xlink:title="central spacer grid" id="ABBRID0EHLAC">CSG</abbrev>. In this case, the difference between the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0ELLAC">TET</abbrev> readings inside of the <abbrev xlink:title="spacer grid" id="ABBRID0EPLAC">SG</abbrev> and on the <abbrev xlink:title="electroheated fuel element simulator" id="ABBRID0ETLAC">EHFES</abbrev> cladding may exceed 100°C with high <abbrev xlink:title="electroheated fuel element simulator" id="ABBRID0EXLAC">EHFES</abbrev> heat-up rates (over 3°C/s). If the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0E2LAC">TET</abbrev> contacts the <abbrev xlink:title="spacer grid" id="ABBRID0E6LAC">SG</abbrev> but the hot junction is outside of the <abbrev xlink:title="spacer grid" id="ABBRID0EDMAC">SG</abbrev> (Fig. <xref ref-type="fig" rid="F2">2b</xref>), the spacer grid effect is much smaller. For each mode, in this case, the difference between the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0ELMAC">TET</abbrev> readings inside of the <abbrev xlink:title="spacer grid" id="ABBRID0EPMAC">SG</abbrev> and on the <abbrev xlink:title="electroheated fuel element simulator" id="ABBRID0ETMAC">EHFES</abbrev> cladding did not exceed 30°C. A quantitative <abbrev xlink:title="spacer grid" id="ABBRID0EXMAC">SG</abbrev> effect in each <abbrev xlink:title="thermoelectric transducer" id="ABBRID0E2MAC">TET</abbrev> installation option was determined in an experiment on the laboratory facility.</p>
      <fig id="F2" position="float" orientation="portrait">
        <object-id content-type="doi">10.3897/nucet.4.29838.figure2</object-id>
        <object-id content-type="arpha">4B57532F-00AE-52B7-A2E0-C1A6B22BE38A</object-id>
        <label>Figure 2.</label>
        <caption>
          <p><abbrev xlink:title="thermoelectric transducer" id="ABBRID0EHNAC">TET</abbrev> hot junction attachment points: а) – in the <abbrev xlink:title="spacer grid" id="ABBRID0ELNAC">SG</abbrev> plane ; b) – 7 mm above the <abbrev xlink:title="spacer grid" id="ABBRID0EPNAC">SG</abbrev> plane; <abbrev xlink:title="thermoelectric transducer" id="ABBRID0ETNAC">TET</abbrev> forced against the <abbrev xlink:title="spacer grid" id="ABBRID0EXNAC">SG</abbrev> cladding (1), <abbrev xlink:title="thermoelectric transducer" id="ABBRID0E2NAC">TET</abbrev> forced against the cladding by means of wire binding (2)</p>
        </caption>
        <graphic xlink:href="nucet-04-e29838-g002.jpg" position="float" orientation="portrait" xlink:type="simple" id="oo_236043.jpg">
          <uri content-type="original_file">https://binary.pensoft.net/fig/236043</uri>
        </graphic>
      </fig>
      <p>Fig. <xref ref-type="fig" rid="F3">3</xref> presents the value of the difference in the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EKOAC">TET</abbrev> readings inside of the <abbrev xlink:title="spacer grid" id="ABBRID0EOOAC">SG</abbrev> and on the <abbrev xlink:title="electroheated fuel element simulator" id="ABBRID0ESOAC">EHFES</abbrev> cladding as a function of the growth rate for the two hot junction locations: inside of the <abbrev xlink:title="spacer grid" id="ABBRID0EWOAC">SG</abbrev> (for the <abbrev xlink:title="central spacer grid" id="ABBRID0E1OAC">CSG</abbrev>) and at a distance of about 5 to 7 mm (for the <abbrev xlink:title="lower spacer grid" id="ABBRID0E5OAC">LSG</abbrev>).</p>
      <!--PageBreak-->
      <p>According to the data shown in Fig. <xref ref-type="fig" rid="F3">3</xref> and Table <xref ref-type="table" rid="T1">1</xref>, the option with the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0ENPAC">TET</abbrev> hot junction being above the <abbrev xlink:title="spacer grid" id="ABBRID0ERPAC">SG</abbrev> plane is the preferred one since the corrections to the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EVPAC">TET</abbrev> readings are smaller in this case.</p>
      <p>The values of the corrections to the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0E2PAC">TET</abbrev> readings with the hot junction installed:</p>
      <p>– inside of the <abbrev xlink:title="spacer grid" id="ABBRID0ECAAE">SG</abbrev>: 80–100°C for the growth rate of the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EGAAE">TET</abbrev> readings in the limits of 2.0–3.0°C/s;</p>
      <p>– 5 to 7 mm above the spacer grid plane: 20–30°C for the growth rate of the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EMAAE">TET</abbrev> readings in the limits of 0.5–3.0 C/s.</p>
      <fig id="F3" position="float" orientation="portrait">
        <object-id content-type="doi">10.3897/nucet.4.29838.figure3</object-id>
        <object-id content-type="arpha">3B931C5E-8342-50DB-B1B1-34546657A0C9</object-id>
        <label>Figure 3.</label>
        <caption>
          <p>Variation of the difference in the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EYAAE">TET</abbrev> readings for <italic>Т</italic><sub>4</sub> – <italic>Т</italic><sub>3</sub>, <italic>Т</italic><sub>6</sub> – <italic>Т</italic><sub>5</sub> as a function of the rate of growth in the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EIBAE">TET</abbrev> readings in the <abbrev xlink:title="central spacer grid" id="ABBRID0EMBAE">CSG</abbrev> (1) and in the <abbrev xlink:title="lower spacer grid" id="ABBRID0EQBAE">LSG</abbrev> (2) at 300°C (а) and 600°C (b)</p>
        </caption>
        <graphic xlink:href="nucet-04-e29838-g003.jpg" position="float" orientation="portrait" xlink:type="simple" id="oo_236044.jpg">
          <uri content-type="original_file">https://binary.pensoft.net/fig/236044</uri>
        </graphic>
      </fig>
      <table-wrap id="T1" position="float" orientation="portrait">
        <label>Table 1.</label>
        <caption>
          <p>Values of temperature differences for <italic>Т</italic><sub>2</sub> – <italic>Т</italic><sub>1</sub>, <italic>Т</italic><sub>4</sub> – <italic>Т</italic><sub>3</sub>, <italic>Т</italic><sub>6</sub> – <italic>Т</italic><sub>5</sub> and growth rates of the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EVCAE">TET</abbrev> readings.</p>
        </caption>
        <table id="TID0ERHAC" rules="all">
          <tbody>
            <tr>
              <td rowspan="1" colspan="3">
                <bold><abbrev xlink:title="lower spacer grid" id="ABBRID0ECDAE">LSG</abbrev> region</bold>
              </td>
              <td rowspan="1" colspan="3">
                <bold><abbrev xlink:title="central spacer grid" id="ABBRID0EKDAE">CSG</abbrev> region</bold>
              </td>
              <td rowspan="1" colspan="3">
                <bold><abbrev xlink:title="upper spacer grid" id="ABBRID0ESDAE">USG</abbrev> region</bold>
              </td>
            </tr>
            <tr>
              <td rowspan="2" colspan="1">
                <bold>Т<sub>2</sub> – Т<sub>1</sub>, °С</bold>
              </td>
              <td rowspan="1" colspan="2">
                <bold>Rate, °C/с</bold>
              </td>
              <td rowspan="2" colspan="1">
                <bold>Т<sub>4</sub> – Т<sub>3</sub>, °С</bold>
              </td>
              <td rowspan="1" colspan="2">
                <bold>Rate, °C/с</bold>
              </td>
              <td rowspan="2" colspan="1">
                <bold>Т<sub>6</sub> – Т<sub>5</sub>, °С</bold>
              </td>
              <td rowspan="1" colspan="2">
                <bold>Rate, °C/с</bold>
              </td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">
                <bold>in <abbrev xlink:title="lower spacer grid" id="ABBRID0EEFAE">LSG</abbrev></bold>
              </td>
              <td rowspan="1" colspan="1">
                <bold>above <abbrev xlink:title="lower spacer grid" id="ABBRID0EMFAE">LSG</abbrev></bold>
              </td>
              <td rowspan="1" colspan="1">
                <bold>in <abbrev xlink:title="central spacer grid" id="ABBRID0EUFAE">CSG</abbrev></bold>
              </td>
              <td rowspan="1" colspan="1">
                <bold>above <abbrev xlink:title="central spacer grid" id="ABBRID0E3FAE">CSG</abbrev></bold>
              </td>
              <td rowspan="1" colspan="1">
                <bold>in <abbrev xlink:title="upper spacer grid" id="ABBRID0EEGAE">USG</abbrev></bold>
              </td>
              <td rowspan="1" colspan="1">
                <bold>above <abbrev xlink:title="upper spacer grid" id="ABBRID0EMGAE">USG</abbrev></bold>
              </td>
            </tr>
            <tr>
              <td rowspan="1" colspan="9">
                <bold>Mode 1</bold>
              </td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">72</td>
              <td rowspan="1" colspan="1">0.22</td>
              <td rowspan="1" colspan="1">0.43</td>
              <td rowspan="1" colspan="1">30</td>
              <td rowspan="1" colspan="1">0.29</td>
              <td rowspan="1" colspan="1">0.46</td>
              <td rowspan="1" colspan="1">13</td>
              <td rowspan="1" colspan="1">0.37</td>
              <td rowspan="1" colspan="1">0.48</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">83</td>
              <td rowspan="1" colspan="1">0.34</td>
              <td rowspan="1" colspan="1">0.57</td>
              <td rowspan="1" colspan="1">33</td>
              <td rowspan="1" colspan="1">0.39</td>
              <td rowspan="1" colspan="1">0.57</td>
              <td rowspan="1" colspan="1">13</td>
              <td rowspan="1" colspan="1">0.5</td>
              <td rowspan="1" colspan="1">0.62</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">79</td>
              <td rowspan="1" colspan="1">0.29</td>
              <td rowspan="1" colspan="1">0.51</td>
              <td rowspan="1" colspan="1">27</td>
              <td rowspan="1" colspan="1">0.4</td>
              <td rowspan="1" colspan="1">0.55</td>
              <td rowspan="1" colspan="1">15</td>
              <td rowspan="1" colspan="1">0.45</td>
              <td rowspan="1" colspan="1">0.6</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">84</td>
              <td rowspan="1" colspan="1">0.41</td>
              <td rowspan="1" colspan="1">0.7</td>
              <td rowspan="1" colspan="1">25</td>
              <td rowspan="1" colspan="1">0.54</td>
              <td rowspan="1" colspan="1">0.75</td>
              <td rowspan="1" colspan="1">18</td>
              <td rowspan="1" colspan="1">0.64</td>
              <td rowspan="1" colspan="1">0.83</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="9">
                <bold>Mode 2</bold>
              </td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">166</td>
              <td rowspan="1" colspan="1">1.96</td>
              <td rowspan="1" colspan="1">3.24</td>
              <td rowspan="1" colspan="1">96</td>
              <td rowspan="1" colspan="1">2.8</td>
              <td rowspan="1" colspan="1">3.84</td>
              <td rowspan="1" colspan="1">22</td>
              <td rowspan="1" colspan="1">2.97</td>
              <td rowspan="1" colspan="1">3.2</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">90</td>
              <td rowspan="1" colspan="1">1.38</td>
              <td rowspan="1" colspan="1">2.77</td>
              <td rowspan="1" colspan="1">50</td>
              <td rowspan="1" colspan="1">1.78</td>
              <td rowspan="1" colspan="1">3</td>
              <td rowspan="1" colspan="1">8</td>
              <td rowspan="1" colspan="1">0.91</td>
              <td rowspan="1" colspan="1">0.78</td>
            </tr>
          </tbody>
        </table>
      </table-wrap>
    </sec>
    <sec sec-type="Use of the results obtained in computational modeling of the reactor experiment parameters" id="SECID0EBMAE">
      <title>Use of the results obtained in computational modeling of the reactor experiment parameters</title>
      <p>The results obtained were used to determine the temperature of the high burnup fuel cladding in experiments (<xref ref-type="bibr" rid="B18">Shulimov et al. 2015</xref>; <xref ref-type="bibr" rid="B14">Izhutov et al. 2015</xref>; <xref ref-type="bibr" rid="B3">Alekseev et al. 2016</xref>; <xref ref-type="bibr" rid="B11">Goncharov et al. 2016</xref>; <xref ref-type="bibr" rid="B4">Alekseev et al. 2017a</xref>, <xref ref-type="bibr" rid="B5">b</xref>) in the MIR research reactor channels with simulated parameters of the <abbrev xlink:title="loss-of-coolant accident" id="ABBRID0E6MAE">LOCA</abbrev> accident in the VVER-1000 reactor (<xref ref-type="bibr" rid="B20">Spasskov et al. 1998</xref>; <xref ref-type="bibr" rid="B7">Alekseev et al. 2007b</xref>). The experimental results correlated well with the data obtained in the post-test examination of the tested fuel and were confirmed by computational modeling of the data.</p>
      <p>Figs <xref ref-type="fig" rid="F4">4</xref> and <xref ref-type="fig" rid="F5">5</xref> show the results of two experiments (<xref ref-type="bibr" rid="B3">Alekseev et al. 2016</xref>; <xref ref-type="bibr" rid="B11">Goncharov et al. 2016</xref>; <xref ref-type="bibr" rid="B4">Alekseev et al. 2017a</xref>): the maximum cladding temperature in the first experiment was 805°C, and the maximum cladding temperature in the second experiment was 760°C. Additionally, computational modeling results obtained for the <abbrev xlink:title="central spacer grid" id="ABBRID0EDOAE">CSG</abbrev> installed in the maximum power density region are presented.</p>
      <p>The height coordinate, at which the maximum cladding temperature is reached, coincides with the coordinate of the maximum circumferential deformation measured in the shielded box.</p>
      <fig id="F4" position="float" orientation="portrait">
        <object-id content-type="doi">10.3897/nucet.4.29838.figure4</object-id>
        <object-id content-type="arpha">5EE8CA8D-FC96-5C6C-AD1F-B3F320BE0B14</object-id>
        <label>Figure 4.</label>
        <caption>
          <p>Time-temperature curve for experiment 1: <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EQOAE">TET</abbrev> readings (1); cladding temperature values determined using the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EUOAE">TET</abbrev> readings with corrections taken into account (2); calculated cladding temperature values (3)</p>
        </caption>
        <graphic xlink:href="nucet-04-e29838-g004.jpg" position="float" orientation="portrait" xlink:type="simple" id="oo_236045.jpg">
          <uri content-type="original_file">https://binary.pensoft.net/fig/236045</uri>
        </graphic>
      </fig>
      <fig id="F5" position="float" orientation="portrait">
        <object-id content-type="doi">10.3897/nucet.4.29838.figure5</object-id>
        <object-id content-type="arpha">C7F3ED42-1BE4-5C45-BC95-23A081227F34</object-id>
        <label>Figure 5.</label>
        <caption>
          <p>Time-temperature curve for experiment 2: <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EFPAE">TET</abbrev> readings (1); cladding temperature values determined using the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EJPAE">TET</abbrev> readings with corrections taken into account (2); calculated cladding temperature values (3)</p>
        </caption>
        <graphic xlink:href="nucet-04-e29838-g005.jpg" position="float" orientation="portrait" xlink:type="simple" id="oo_236046.jpg">
          <uri content-type="original_file">https://binary.pensoft.net/fig/236046</uri>
        </graphic>
      </fig>
    </sec>
    <sec sec-type="Conclusions" id="SECID0ESPAE">
      <title>Conclusions</title>
      <p>The procedural aspects of measuring the burnup fuel cladding temperature, successfully implemented in the experimental practice in the MIR reactor channels, have been analyzed, in which one of the major parameters studied is deformation of the cladding in a temperature range of 700–900°C.</p>
      <p>The results of studying the thermometric characteristic of the <abbrev xlink:title="thermoelectric transducer" id="ABBRID0EZPAE">TET</abbrev> attachment in a spacer grid are presented. Using a laboratory facility, in which a fuel element simulator with internal electroheating was employed, a system of corrections was determined for determining the cladding temperature.</p>
      <p>The reliability of the burnup fuel cladding temperature determination results has been confirmed by results of post-test examinations and by results of the experimental data computational modeling.</p>
    </sec>
  </body>
  <back>
    <ref-list>
      <title>References</title>
      <ref id="B1">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Alekseev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Burukin</surname><given-names>AV</given-names></name><name name-style="western"><surname>Izhutov</surname><given-names>AL</given-names></name><name name-style="western"><surname>Kalygin</surname><given-names>VV</given-names></name><name name-style="western"><surname>Kiseleva</surname><given-names>IV</given-names></name><name name-style="western"><surname>Ovchinnikov</surname><given-names>VA</given-names></name><name name-style="western"><surname>Shulimov</surname><given-names>VN</given-names></name></person-group> (<year>2007a</year>) <article-title>Methods to test VVER fuel in the MIR reactor under transient and accidental conditions. Izvestiya vuzov.</article-title><source>Yadernaya Energetika</source><volume>3</volume>: <fpage>83</fpage>–<lpage>91</lpage>. [in Russian]</mixed-citation>
      </ref>
      <ref id="B2">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Alekseev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Burukin</surname><given-names>AV</given-names></name><name name-style="western"><surname>Izhutov</surname><given-names>AL</given-names></name><name name-style="western"><surname>Kalygin</surname><given-names>VV</given-names></name><name name-style="western"><surname>Kiseleva</surname><given-names>IV</given-names></name><name name-style="western"><surname>Ovchinnikov</surname><given-names>VA</given-names></name><name name-style="western"><surname>Shulimov</surname><given-names>VN</given-names></name></person-group> (<year>2012</year>) <article-title>Programs and Methods for Testing in the MIR research Reactor Fuel Elements of Water-Cooled Reactors under Conditions Simulating Transient and Emergency Ones.</article-title><source>Atomnaya Energiya</source><volume>113</volume>(<issue>3</issue>): <fpage>146</fpage>–<lpage>150</lpage>. [in Russian]</mixed-citation>
      </ref>
      <ref id="B3">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Alekseev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Goryachev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Dreganov</surname><given-names>OI</given-names></name><name name-style="western"><surname>Izhutov</surname><given-names>AL</given-names></name><name name-style="western"><surname>Kireeva</surname><given-names>LV</given-names></name><name name-style="western"><surname>Kiseleva</surname><given-names>IV</given-names></name><name name-style="western"><surname>Shulimov</surname><given-names>VN</given-names></name><name name-style="western"><surname>Kuznetsov</surname><given-names>VI</given-names></name><name name-style="western"><surname>Novikov</surname><given-names>VV</given-names></name><name name-style="western"><surname>Salatov</surname><given-names>AV</given-names></name><name name-style="western"><surname>Fedotov</surname><given-names>PV</given-names></name></person-group> (<year>2016</year>) Investigation of VVER-1000 fuel rods behavior under LOCA. MIR-LOCA/45 and MIR-LOCA/69 experiments. Proc. of JSC «TVEL» Scientific Conference «New Generation Nuclear Fuel for NPPs», 16–17 November, Moscow, 38. [in Russian]</mixed-citation>
      </ref>
      <ref id="B4">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Alekseev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Goryachev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Dreganov</surname><given-names>OI</given-names></name><name name-style="western"><surname>Kireeva</surname><given-names>LV</given-names></name><name name-style="western"><surname>Kiseleva</surname><given-names>IV</given-names></name><name name-style="western"><surname>Shulimov</surname><given-names>VN</given-names></name></person-group> (<year>2017a</year>) <article-title>Study of VVER-1000 Fuel Rod Behavior under LOCA Conditions. RIAR Proceedings.</article-title><source>JSC «SSC RIAR», Dimitrovgrad</source><volume>1</volume>: <fpage>12</fpage>–<lpage>20</lpage>. [in Russian]</mixed-citation>
      </ref>
      <ref id="B5">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Alekseev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Goryachev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Dreganov</surname><given-names>OI</given-names></name><name name-style="western"><surname>Kireeva</surname><given-names>LV</given-names></name><name name-style="western"><surname>Kiseleva</surname><given-names>IV</given-names></name><name name-style="western"><surname>Shulimov</surname><given-names>VN</given-names></name></person-group> (<year>2017b</year>) Study of high-burnup VVER-1000 Fuel Rod Behavior under LOCA Conditions. Experiment-LOCA/72. Proc. of the X<sup>th</sup> International Scientific and Technical Conference «Safety Assurance of NPP with VVER», 16–19 May, Russia, Podolsk: 102–103. [in Russian]</mixed-citation>
      </ref>
      <ref id="B6">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Alekseev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Goryachev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Kalygin</surname><given-names>VV</given-names></name><name name-style="western"><surname>Kiseleva</surname><given-names>IV</given-names></name><name name-style="western"><surname>Shulimov</surname><given-names>VN</given-names></name></person-group> (<year>2009</year>) VVER-1000 Fuel Irradiation in the MIR Reactor under Conditions Simulating II and III Stage of Design Basis “Large Leak” Accident. Izvestiya vuzov. Yadernaya Energetika (4): 132–136. [in Russian]</mixed-citation>
      </ref>
      <ref id="B7">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Alekseev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Goryachev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Kiseleva</surname><given-names>IV</given-names></name><name name-style="western"><surname>Shulimov</surname><given-names>VN</given-names></name></person-group> (<year>2007b</year>) <article-title>Procedure and results of testing a VVER-1000 FA fragment in the MIR reactor channel under the maximum design-basis accident (stages II and III).</article-title><source>Atomnaya Energiya</source><volume>103</volume>(<issue>5</issue>): <fpage>286</fpage>–<lpage>291</lpage>. [in Russian] <ext-link xlink:type="simple" ext-link-type="doi" xlink:href="10.1007/s10512-007-0135-7">https://doi.org/10.1007/s10512-007-0135-7</ext-link></mixed-citation>
      </ref>
      <ref id="B8">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Alekseev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Kiseleva</surname><given-names>IV</given-names></name><name name-style="western"><surname>Malkov</surname><given-names>AP</given-names></name><name name-style="western"><surname>Shulimov</surname><given-names>VN</given-names></name></person-group> (<year>2006a</year>) <article-title>Studying of the VVER fuel behavior under the control rod ejection accident conditions. In-pile test method and procedure.</article-title><source>RIAR Proceedings</source><volume>1</volume>: <fpage>23</fpage>–<lpage>32</lpage>. [in Russian]</mixed-citation>
      </ref>
      <ref id="B9">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Alekseev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Kiseleva</surname><given-names>IV</given-names></name><name name-style="western"><surname>Ovchinnikov</surname><given-names>VA</given-names></name><name name-style="western"><surname>Shulimov</surname><given-names>VN</given-names></name></person-group> (<year>2006b</year>) <article-title>VVER-1000 fuel testing method in the MIR reactor under the control rod ejection accident conditions.</article-title><source>Atomnaya Energiya</source><volume>101</volume>(<issue>6</issue>): <fpage>427</fpage>–<lpage>431</lpage>. [in Russian] <ext-link xlink:type="simple" ext-link-type="doi" xlink:href="10.1007/s10512-006-0185-2">https://doi.org/10.1007/s10512-006-0185-2</ext-link></mixed-citation>
      </ref>
      <ref id="B10">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Askeljung</surname><given-names>P</given-names></name><name name-style="western"><surname>Flygare</surname><given-names>J</given-names></name><name name-style="western"><surname>Minghetti</surname><given-names>D</given-names></name></person-group> (<year>2012</year>) Studsvik Nuclear AB, SE-611 82, Nykoping, Sweden NRC LOCA testing program at Studsvik, recent results on high burnup fuel (TopFuel 2012-a0117).</mixed-citation>
      </ref>
      <ref id="B11">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Goncharov</surname><given-names>AA</given-names></name><name name-style="western"><surname>Kuznetsov</surname><given-names>VI</given-names></name><name name-style="western"><surname>Kumachev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Nechaeva</surname><given-names>OA</given-names></name><name name-style="western"><surname>Novikov</surname><given-names>VV</given-names></name><name name-style="western"><surname>Salatov</surname><given-names>AV</given-names></name><name name-style="western"><surname>Fedotov</surname><given-names>PV</given-names></name></person-group> (<year>2016</year>) Experiments and calculation to study high-burnup VVER fuel behavior under design-basis accidents. Proc. of JSC «TVEL» Scientific Conference «New Generation Nuclear Fuel for NPPs», 16–17 November, Moscow, 36. [in Russian]</mixed-citation>
      </ref>
      <ref id="B12">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Goryachev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Kiseleva</surname><given-names>IV</given-names></name><name name-style="western"><surname>Makhin</surname><given-names>VM</given-names></name><name name-style="western"><surname>Shulimov</surname><given-names>VN</given-names></name></person-group> (<year>2004a</year>) <article-title>Integral In-Pile Experiments with VVER-440 and VVER-1000 Multielement Fuel Test Rigs under the LOCA Conditions. Izvestiya vuzov.</article-title><source>Yadernaya Energetika</source><volume>3</volume>: <fpage>50</fpage>–<lpage>58</lpage> [in Russian]</mixed-citation>
      </ref>
      <ref id="B13">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Goryachev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Makhin</surname><given-names>VM</given-names></name><name name-style="western"><surname>Kiseleva</surname><given-names>IV</given-names></name><name name-style="western"><surname>Shulimov</surname><given-names>VN</given-names></name></person-group> (<year>2004</year>) <article-title>Integral In-Pile Experiments with VVER-440 and VVER-1000 Multielement Fuel Test Rigs under the LOCA Conditions. Compilation of Experimental Data from a series of Tests. VANT. Ser.</article-title><source>Fisika Yadernykh Reaktorov</source><volume>2</volume>: <fpage>29</fpage>–<lpage>38</lpage>. [in Russian]</mixed-citation>
      </ref>
      <ref id="B14">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Izhutov</surname><given-names>AL</given-names></name><name name-style="western"><surname>Dreganov</surname><given-names>OI</given-names></name><name name-style="western"><surname>Kisseleva</surname><given-names>IV</given-names></name><name name-style="western"><surname>Shulimov</surname><given-names>VN</given-names></name></person-group> (<year>2015</year>) Researches of VVER high burn-up fuel behavior under LOCA conditions. Joint Halden Reactor Project NEA Working Group on Fuel safety LOCA Workshop. Aix-en Provence, France, May 20–21.</mixed-citation>
      </ref>
      <ref id="B15">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Kekkonen</surname><given-names>Laura</given-names></name></person-group> (<year>2008</year>) “LOCA testing at Halden In-pile results from the VVER LOCA test IFA-650.6 (HWR-870)”. EHPG Meeting, 18–23 May, Loen.</mixed-citation>
      </ref>
      <ref id="B16">
        <mixed-citation xlink:type="simple"><institution xlink:type="simple">Research Reactors of RIAR and their Experimental Capabilities under Scientific Editorship of Prof. V.A. Tsykanov</institution> (<year>1991</year>) NIIAR Publ., Dimitrovgrad, 103 pp. [in Russian]</mixed-citation>
      </ref>
      <!--PageBreak-->
      <ref id="B17">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Salatov</surname><given-names>AV</given-names></name><name name-style="western"><surname>Kumachev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Nechaeva</surname><given-names>OA</given-names></name><name name-style="western"><surname>Novikov</surname><given-names>VV</given-names></name><name name-style="western"><surname>Fedotov</surname><given-names>PV</given-names></name><name name-style="western"><surname>Alekseev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Goryachev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Kiseleva</surname><given-names>IV</given-names></name><name name-style="western"><surname>Shulimov</surname><given-names>VN</given-names></name><name name-style="western"><surname>Bykov</surname><given-names>MA</given-names></name><name name-style="western"><surname>Makhin</surname><given-names>VM</given-names></name><name name-style="western"><surname>Zaytsev</surname><given-names>SI</given-names></name><name name-style="western"><surname>Zakutaev</surname><given-names>MO</given-names></name><name name-style="western"><surname>Lyutov</surname><given-names>KV</given-names></name><name name-style="western"><surname>Pylev</surname><given-names>SS</given-names></name><name name-style="western"><surname>Tebin</surname><given-names>VV</given-names></name><name name-style="western"><surname>Shchepetilnikov</surname><given-names>EYu</given-names></name><name name-style="western"><surname>Gusev</surname><given-names>AS</given-names></name><name name-style="western"><surname>Pimenov</surname><given-names>YuV</given-names></name></person-group> (<year>2013</year>) <article-title>Experimental and Computational Studies of VVER Fuel Behavior under LOCA Conditions (MIR-LOCA/60 Test). VANT. Ser.</article-title><source>Materialovedenie i Novye Materialy</source><volume>1</volume>(<issue>74</issue>): <fpage>26</fpage>–<lpage>38</lpage>. [in Russian]</mixed-citation>
      </ref>
      <ref id="B18">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Shulimov</surname><given-names>VN</given-names></name><name name-style="western"><surname>Dreganov</surname><given-names>OI</given-names></name><name name-style="western"><surname>Izhutov</surname><given-names>AL</given-names></name><name name-style="western"><surname>Kisseleva</surname><given-names>IV</given-names></name><name name-style="western"><surname>Gorychev</surname><given-names>FV</given-names></name><name name-style="western"><surname>Alexeev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Fedotov</surname><given-names>PV</given-names></name><name name-style="western"><surname>Kumachev</surname><given-names>AV</given-names></name><name name-style="western"><surname>Kuznetsov</surname><given-names>VI</given-names></name><name name-style="western"><surname>Novikov</surname><given-names>VV</given-names></name><name name-style="western"><surname>Salatov</surname><given-names>AV</given-names></name><name name-style="western"><surname>Sypchenko</surname><given-names>MV</given-names></name><name name-style="western"><surname>Pimenov</surname><given-names>YuV</given-names></name></person-group> (<year>2015</year>) LOCA test with high burnup VVER fuel in MIR reactor. TopFuel conference Proceedings Part II, Zurich, Switzerland, 13–17 September, 391–400. <ext-link xlink:type="simple" ext-link-type="uri" xlink:href="http://www.topfuel2015.org">http://www.topfuel2015.org</ext-link></mixed-citation>
      </ref>
      <ref id="B19">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Shulimov</surname><given-names>VN</given-names></name><name name-style="western"><surname>Kiseleva</surname><given-names>IV</given-names></name></person-group> (<year>2004</year>) Experiment- and Calculation-Based Estimation of Fuel in the Course of Rapid In-Pile «Large Break Loss of Coolant Accident-2» (BT-2). «Experimental Data Analysis and Verification of Computer Codes». Proc. of Workshop Abstracts. Sosnovy Bor, October 4–8. Research Institute of Technology n.a. A.P.Alexandrov: 98–100. [in Russian]</mixed-citation>
      </ref>
      <ref id="B20">
        <mixed-citation xlink:type="simple"><person-group><name name-style="western"><surname>Spasskov</surname><given-names>VP</given-names></name><name name-style="western"><surname>Shumsky</surname><given-names>AM</given-names></name><name name-style="western"><surname>Semishkin</surname><given-names>VP</given-names></name></person-group> (<year>1998</year>) In-Pile Testing of the VVER Core Emergency Performance in the Loop Test Facility PVP-2 in the MIR reactor. Proc. of Int. Conf. «Thermal Physics-98», SSC RF-IPPE, Obninsk, 2: 42–51. [in Russian]</mixed-citation>
      </ref>
    </ref-list>
    <fn-group>
      <fn id="fntitle">
        <p>* Russian text published: Izvestiya vuzov. Yadernaya Energetika (ISSN 0204-3327), 2017, n.4, pp. 50–60</p>
      </fn>
    </fn-group>
  </back>
</article>
