Measured air temperature values for the containment rooms in units 1 and 2 of the Novovoronezh NPP II as a function of the outdoor air temperature (toa): a) temperature in the containment’s central hall (design temperature value 40 °C); b) temperature in the region of the CPS control members and the upper unit (design temperature value 100 °C, scram setpoint temperature value 120 °C); c) steam generator compartment temperature (design temperature value 60 °C).

 
 
  Part of: Soloviev SL, Shishov AV, Povarov VP, Yaurov SV (2024) Computational simulation of the heat and mass transfer processes occurring in the containment of Novovoronezh NPP II’s units 1 and 2. Nuclear Energy and Technology 10(1): 19-25. https://doi.org/10.3897/nucet.10.122292