BOR-60 thermal circuit: 1 – reactor; 2 – sodium-sodium heat exchanger; 3 – pump; 4 – sodium- air heat exchanger (AHX); 5 – AHX fans; 6 – AHX buffer tank; 7 – steam generator (SG); 8 – SG buffer tank; 9 – separator; 10 – turbine generator; 11 – turbine condenser; 12 – ejector; 13 – low-pressure preheater; 14 – feedwater pump; 15 – high-pressure preheater; 16 – process condenser; 17 – deaerator.

 
 
  Part of: Borisov VV, Kamaev AA, Myazdrikova OI, Mikhin SA, Pakhomov IA, Perevoznikov SV (2023) Principles of construction and development of an automatic protection system for steam generators of fast reactors. Nuclear Energy and Technology 9(4): 259-266. https://doi.org/10.3897/nucet.9.116657